background image

34

W415-0762 / A / 07.19.10

 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not 
necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. Provided that the 
purchase was made through an authorized NAPOLEON® dealer your fi replace is subject to the following conditions and limitations:
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The wood fi replace must be installed by an authorized service technician or contractor. Installation must be done in accordance with 
the installation instructions included with the product and all local and national building and fi re codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and 
parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and 
chemical cleaners nor chipping on porcelain enamel parts, nor any venting components used in the installation of the fi replace.
In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or 
workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to the President’s Lifetime Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all 
obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but 
defective part(s).
After the fi rst year, NAPOLEON® will not be responsible for installation, labour or any other costs or expenses related to the 
reinstallation of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, NAPOLEON’s responsibility under this warranty 
is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® wood fi replace and any other 
warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale 
of this product. NAPOLEON® will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such 
as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient 
makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, 
clothes dryers, etc.
Any damages to fi replace, combustion chamber, heat exchanger, brass trim or other component  due to water, weather damage, long 
periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.
NAPOLEON® reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

2.2

NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 

Quality Assurance Certifi cate.

NAPOLEON® products are designed with superior components and materials, assembled by trained 

craftsmen who take great pride in their work. The complete fi replace is again thoroughly inspected by a 

qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you 

expect from NAPOLEON®.

The following materials and workmanship in your new NAPOLEON® wood fi replace are warranted 
against defects for as long as you own the fi replace. This covers: combustion chamber, heat exchanger, 
stainless steel baffl e retainer, ceramic glass (thermal breakage only), gold plated parts against tarnishing, 
porcelainized enameled components, aluminum extrusion trims ash drawer and cast iron castings.

Electrical (110V) components and wearable parts such as blowers, thermal switch, switches, wiring, 
fi rebrick, and gasketing are covered and NAPOLEON® will provide replacement parts free of charge during 
the fi rst year of the limited warranty. 

Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, 
requires the prior approval of an authorized company offi cial. Labour costs to the account of NAPOLEON® 
are based on a predetermined rate schedule and any repair work must be done through an authorized 
NAPOLEON® dealer.

NAPOLEON® WOOD FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY

CONDITIONS AND LIMITATIONS

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT 

IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 

2.073.411, 2.082.915. © WOLF STEEL LTD.

11.0 WARRANTY

Summary of Contents for 1100PL

Page 1: ...al building or fire authority and follow their guidelines Operate only with the door tightly closed Burn wood behind the log retainer directly on the firebricks Do not use an elevated grate or otherwi...

Page 2: ...TION 1100PL 1400PL 19 5 2 DOOR REMOVAL INSTALLATION 1100PL 1400PL 19 5 3 1100C 1400C DOOR REMOVAL INSTALLATION 19 5 4 1400C CAST LID LEVELLING 20 5 5 DOOR HANDLE INSTALLATION 20 5 6 BRICKS AND BAFFLES...

Page 3: ...OVERVIEW Legs see LEG INSTAL LATION section Blower see OPTIONAL BLOWER KIT INSTAL LATION section Ash drawer see OPTIONAL ASH DRAWER KIT section Door see DOOR AND HANDLE INSTALLATION section Draft see...

Page 4: ...o circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a seperate solid fuel burning appliance Do not operate the appliance with the gl...

Page 5: ...4 12 3 4 14 HEIGHT LEG MODEL E 32 28 1 2 32 28 1 2 CHAMBER D W H 13 1 2x18x12 13 1 2x18x12 18x18x12 18x18x12 CAPACITY 1 7ft3 1 7ft3 2 25ft3 2 25ft3 APPROX AREA HEATED 600 1500 ft2 600 1500 ft2 1000 20...

Page 6: ...re DURING THIS PROCESS DO NOT OVERFIRE THE APPLIANCE REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED 4 7 ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN...

Page 7: ...stion chamber is lined with high temperature firebrick on 2 sides the back and across the bottom with a layer of fibre baffles at the top to maintain a high temperature in the combustion chamber so th...

Page 8: ...MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION RENSEIGNEZ VOUS AUPR S DESAUTORIT S LOCALES DU B TIMENT ET DU SERVICE DES INCENDIESAU SUJET...

Page 9: ...FEET CEILING OF ENCLOSURE TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT WARNING BACK WALL B SIDE WALL A BACK WALL C SIDE WALL F D E E PARALLEL CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR 1100PL...

Page 10: ...xhaust house air The house has tight fitting windows and or is equipped with a well sealed vapour barrier 3 5 1 Connection from the appliance s air intake to the outside is mandatory in mobile homes o...

Page 11: ...licone to maintain a vapour barrier at the chimney and outside air pipe penetrations DO NOT INSTALL IN SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAI...

Page 12: ...E THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM...

Page 13: ...MISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIGHT ABOVE THE STOVE ALL HORIZONTAL SMOK...

Page 14: ...to 10 In the case of vertical installation the total length of the connector can be longer and connected without problem to the chimney at the ceiling level There should never be more than two 90 elb...

Page 15: ...ney must extend at least 3 feet above its point of contact with the roof and at least 2 feet higher than any wall roof building or obstacle within 10 feet horizontally 59 1A 3 FT MIN 3 FT MIN 3 FT MIN...

Page 16: ...hat the chimney passes through If your chimney system is enclosed within the attic area a rafter radiation shield is required C Hold a plumb bob from the underside of the roof to determine where the o...

Page 17: ...or any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall...

Page 18: ...you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must normally be lined with fire clay bricks metal or clay...

Page 19: ...n all four legs Do not pivot appliance up on its legs as this could result in damage to the legs 5 0 FINISHING 5 2 DOOR REMOVAL INSTALLATION 1100PL 1400PL PINS 5 2 1 Pivot the door open and lift up to...

Page 20: ...E DOOR WHEN THE APPLIANCE IS HOT WARNING DOOR HANDLE NUT DOOR HANDLE LATCH LOCK WASHER DOOR SPACER SPRING WASHER FRONT VIEW NOTE Position of door handle latch NOTE DOOR MAY NOT BE AS ILLUSTRATED 5 4 1...

Page 21: ...the rear of the firebox leaving a minimum of a 1 gap along the front This will allow the flue gases to escape the firebox 5 6 3 Install the 4 bricks along the front NOTE Do not operate if baffle and...

Page 22: ...ows for convenient removal of excess ash This kit can be purchased through your authorized dealer distributor 6 0 OPTIONAL KIT INSTALLATIONS IMPROPER DISPOSAL OF ASHES RESULT IN FIRES DO NOT DISCARD A...

Page 23: ...liance will perform normally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline crac...

Page 24: ...ppliance ensure that the two upper fibre baffles are not lifted up and off their ledge For maximum efficiency when the appliance is thoroughly hot load it fully to the top of the door opening and burn...

Page 25: ...installed appliance should not smoke If yours does check the following Has the chimney had time to get hot Is the smoke passage blocked anywhere in the appliance chimney connector or chimney Is the r...

Page 26: ...CREOSOTE FORMATION AND REMOVAL 8 1 1 APPLIANCES WITHOUT ASH PAN Since some models will not have ash pans shovel some ashes out through the door into a metal container with a tight fitting lid The ashe...

Page 27: ...ct the chimney for stress and cracks prior to lighting an other fire Also check combustibles around the chimney and the roof A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM THIS DAMAGE CAN O...

Page 28: ...or frame down careful not to scratch the paint 8 5 2 Remove the screws and brackets holding the glass in place Remove all broken glass 8 5 3 Wrap the edges of the new glass with a U shaped strip of fi...

Page 29: ...ntil the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 HOT GLASS WILL CAUSE BURNS DO NOT TO...

Page 30: ...the wood will roll onto the glass DO S Build a hot fire Use only dry wood Several pieces of medium sized wood are better than a few big pieces Clean chimney regularly Refuel frequently using medium si...

Page 31: ...5 W090 0005 W090 0005 BRICK 4 RIGHT 6 W090 0016 W090 0016 W090 0016 W090 0016 BRICK 5 7 W090 0017 W090 0017 W090 0017 W090 0017 BRICK 6 8 W090 0018 W090 0018 W090 0018 W090 0018 BRICK 8 9 W090 0019 W0...

Page 32: ...T 34 115KT 115KT 115KT 115KT OUTSIDE AIR KIT 35 N A W470 0020 N A W470 0020 MAJOLICA BROWN ENAMEL TOUCH UP AND BRUSH 36 EP62 1 EP62 1 EP62 1 EP62 1 VARIABLE SPEED BLOWER 37 EPA RK N A EPA RK N A SOLID...

Page 33: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Page 34: ...ed NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product NAPOLEON will not be responsible for over firing downd...

Page 35: ...35 W415 0762 A 07 19 10 43 1 12 0 SERVICE HISTORY...