background image

8

W415-0762 / A / 07.19.10

2.5  RATING PLATE LOCATION

1400

1400L

1402

LISTED SOLID FUEL BURNING FIREPLACE INSERT / 
ENCASTRÉ  À COMBUSTIBLE SOLIDE HOMOLOGUÉ

TESTED TO / TESTÉ SELON :

ULC S628 / UL 1482

FROM HEATER / DU POÊLE

RESIDENTIAL / RÉSIDENTIEL

1400

12IN/PO (305 mm)
12IN/PO (305 mm)

6IN/PO (150 mm)

USING DOUBLE  WALL CONNECTOR/UTILISATION

D’UN CONDUIT DE RACCORDEMENT À 

MAISON / MOBILE HOME*

1400

1400

10IN/PO (254 mm)

10IN/PO (254 mm)

6IN/PO (152 mm)

6IN/PO (152 mm)

4IN/PO (102 mm)

4IN/PO (102 mm)

EPI 1402

REFERENCE #15982

INSTALL AND USE ONLY IN 
ACCORDANCE WITH THE 
MANUFACTURER’S 
INSTRUCTIONS AND LOCAL 
BUILDING CODES. 
MINIMUM CEILING HEIGHT: 
7FT (2.13m)

HEARTH EXTENSION / 
COMBUSTIBLE FLOOR 
PROTECTION:

 IF INSTALLED 

ON A COMBUSTIBLE FLOOR, 
UNIT MUST BE PLACED ON A 
NON-COMBUSTIBLE FLOOR 
PROTECTOR EXTENDING 18” 
(455mm) IN FRONT AND 8” 
(205mm) TO THE SIDES AND 
BACK. 

CHIMNEY TYPE:

 MINIMUM 6” 

(152mm) DIAMETER 
APPROVED RESIDENTIAL 
TYPE FOR MOBILE HOME 
USE A CHIMNEY LISTED TO 
ULC S629 IN CANADA OR UL 
103HT IN THE USA.

CHIMNEY CONNECTOR:

 6” 

(152mm) DIAMETER MINIMUM 
24 GAUGE STEEL MINIMUM 
CLEARANCE FROM 
HORIZONTAL CONNECTOR 
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE 
UNDER HEATER.
SPECIAL METHODS ARE 
REQUIRED WHEN PASSING A 
CHIMNEY THROUGH A WALL 
OR CEILING. SEE INSTRUC-
TIONS AND BUILDING 
CODES.
DO NOT CONNECT THIS UNIT 
TO A CHIMNEY FLUE 
SERVING ANOTHER 
APPLIANCE.

FUEL:

 FOR USE WITH WOOD 

ONLY. DO NOT USE GRATE 
OR ELEVATE FIRE. BUILD 
WOOD FIRE DIRECTLY ON 
HEARTH.

WARNING:

 RISK OF SMOKE 

SPILLAGE. OPERATE ONLY 
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH 
CERAMIC GLASS.
DO NOT OVERFIRE. IF 
HEATER OR CHIMNEY 
CONNECTORS GLOW, YOU 
ARE OVERFIRING. INSPECT 
AND CLEAN CHIMNEY 
FREQUENTLY. UNDER 
CERTAIN CONDITIONS OF USE 
CREOSOTE BUILD-UP MAY 
OCCUR RAPIDLY.

OPTIONAL BLOWER KIT:

 

EP-62, 115V, 60HZ, 0.82AMP. 
ROUTE CORD AWAY FROM 
UNIT.

DANGER:

 RISK OF 

ELECTRICAL SHOCK. 
DISCONNECT POWER 
BEFORE SERVICING UNIT.

INSERT:

 INSTALL AND USE 

ONLY IN SOLID FUEL 
BURNING FIREPLACES. DO 
NOT REMOVE BRICKS OR 
MORTAR FROM SOLID FUEL 
BURNING FIREPLACE. 
INSTALL WITH A POSITIVE 
FLUE CONNECTOR AND 
FACEPLATE.

POUR INSTALLATION ET 
UTILISATION CONFORMÉMENT 
AUX INSTRUCTIONS DU 
FABRICANT ET AUX CODES 
LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL 
7PI (2,13m).

PROLONGEMENT 
D’ÂTRE/PROTECTION DU 
PLANCHER COMBUSTIBLE: 

SI 

INSTALLÉ SUR UN PLANCHER 
COMBUSTIBLE, L’APPAREIL DOIT 
ÊTRE PLACÉ SUR UNE PLAQUE 
PROTECTRICE INCOMBUSTIBLE 
S’ÉTENDANT SUR 18” (455mm) 

À 

L’AVANT ET 8” (205mm) À L’ARRIÈRE 
ET SUR LES CÔTÉS.

TYPE DE CHIMNÉE:

 DIAMÈTRE 

MINIMAL DE 6” (152mm) 
APPROUVÉE POUR USAGE 
RÉSIDENTIEL. MAISON MOBILE 
EMPLOYEZ UNE CHEMINÉE 
HOMOLOGUÉE ULC S629 AU 
CANADA OU UL 103HT AUX 
ÉTATS-UNIS.

RACCORD DE CHEMINÉE: 

DIAMÈTRE DE 6” (152mm) D’ACIER 
DE CALIBRE 24 MINIMUM. 18” 
(455mm) DE DÉGAGEMENT 
MINIMAL ENTRE LE RACCORD 
HORIZONTAL ET LE PLAFOND. 
NE RIEN ENTREPOSER SOUS 
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT 
REQUISES LORSQU’UNE 
CHEMINÉE TRAVERSE UN MUR OU 
UN PLAFOND. VOIR LES 
INSTRUCTIONS ET LES CODES DU 
BÂTIMENT. 
NE PAS RACCORDER À LA 
CHEMINÉE D’UN AUTRE APPAREIL.

COMBUSTIBLE:

 POUR USAGE 

AVEC LE BOIS SEULEMENT. 
N’UTILISEZ PAS DE CHENET OU NE 
SURÉLEVEZ PAS LE BOIS. 
PRÉPAREZ LE FEU DIRECTEMENT 
SUR L’ÂTRE.

AVERTISSEMENT: 

RISQUE 

D’ÉCHAPPEMENT DE FUMÉE. 
TENIR LA PORTE FERMÉE 
LORSQUE LE POÊLE FONCTIONNE. 
REMPLACEZ LA VITRE PAR UNE 
VITRE EN CÉRAMIQUE SEULEMENT. 
NE SURCHAUFFEZ PAS 
L’APPAREIL. SI L’APPAREIL OU LES 
RACCORDS ROUGEOIENT, 
L’APPAREIL SURCHAUFEE. 
INSPECTEZ ET NETTOYEZ LA 
CHEMINÉE FRÉQUEMMENT. DANS 
CERTAINES CONDITIONS, DES 
DÉPÔTS DE CRÉOSOTE PEUVENT 
SE FORMER RAPIDEMENT.

SOUFFLERIE OPTIONNELLE: 

EP-62, 115V, 60HZ, 0,82A. TENEZ LE 
CORDON ÉLECTRIQUE LOIN DE 
L’APPAREIL. 

DANGER:

 RISQUE DE SECOUSSE 

ÉLECTRIQUE. DÉBRANCHEZ AVANT 
DE PROCÉDER À L’ENTRETIEN.

ENCASTRÉ: 

INSTALLEZ ET UTILISEZ 

SEULEMENT DANS UN FOYER À 
COMBUSTIBLE SOLIDE. NE 
RETIREZ PAS DE MORTIER, NI 
BRIQUES DU FOYER À COMBUS-
TIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE 
CONFORME ET UNE PLAQUE DE 
RECOUVREMENT.

CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE 
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). A 
MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BE 
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR

ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU 

SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS 
D’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE 
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE 
PRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm) 
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT 
JURIDICTION.

8"

8"

18"

8"

ALCOVE

A"

B"

C

BACK WALL (M/A)

45

°

SIDE W

A

LL

 (M/L)

BACK WALL (M/A)

SIDE W

A

LL

 (M/L)

B

A

IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE 
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT 
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18” 
(455mm) TO THE FRONT.
SI LE PO

ÊLE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ 

SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER 
LES CÔTÉS ET L’AMÉRE DU POÊLE DE 8” (200mm) ET SE PROLONGER DE 18” 
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL 
CHIMNEY CONNECTOR / D

ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX 

COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:

*

MODEL 1400 MAY BE INSTALLED INTO A MOBILE HOME OR COMBUSTIBLE 

ALCOVE USING LISTED DOUBLE WALL CONNECTOR. MODEL 1400 MAY BE 
INSTALLED INTO A MOBILE HOME IN THE UNITED STATES ONLY> 

*

MODÈLE 1400 PEUT ÊTRE INSTALLÉ DANS UNE MAISON MOBILE OU DANS 

UNE ALCÔVE COMBUSTIBLE EN UTILISANT UN CONDUIT DE RACCORDE-
MENT À DOUBLE PAROI CERTIFIÉ. LE MODÈLE 1400 NE PEUT ÊTRE 
INSTALLÉ QUE DANS UNE MAISON MOBILE AUX ÉTATS-UNIS SEULEMENT.

DOUBLE PAROI

CEILING / PLAFOND

C

D

B

A

FLOOR / PLANCHER

HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, 
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

QUAND L’APPAREIL FONCTIONNE, L A SURFACE DEVIENT 
CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LES 
VÊTEMENTS ET LES MEUBLES À L’ÉCAR

T

T.  LE  CONTACT PEUT 

CAUSER DES BRÛLURES À LA PEAU.

CAUTION:

ATTENTION:

U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certifié conforme à la norme d’émanation de particules de juillet 1992.

W385-0401_F

DATE CODE / DE DATE

EPA1400

 SKIN BURNS.

CLEARANCES TO COMBUSTIBLE CONSTRUCTION / 
D

ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES: 

(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)

A  SIDE FACING / CÔTÉ   

1 IN/PO (25mm)

*

B  TOP FACING / DESSUS 

28 IN/PO (710mm)

C  MANTEL / TABLETTE   

28 IN/PO (710mm)

D  SIDE WALL / MUR LATÉRAL 

17 IN/PO (430mm)

*

CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU 

BORD DE LA FAÇADE

LISTED SOLID FUEL BURNING SPACE HEATER / 

POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ 

MODEL / MODÈLE - EPA 1400

TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92)

1450

WOLF STEEL LTD.  

24 Napoleon Rd. Barrie, Ontario L4M 4Y8 Canada

WOLF STEEL USA

103 Miller Drive, Crittenden, Kentucky, USA, 41030

1400C

For rating plate location, 
see “INSTALLATION 
OVERVIEW”

This illustration is for 
reference only.  Refer to 
the rating plate on the 
appliance for accurate 
information.

1400 SERIES RATING PLATE ILLUSTRATED

SAMPLE

F

USING DO

USING DO

M

D

D

’U

M

SMOKE

MOKE 

E ONLY 

ONLY 

OSED.

OSED.

WITH 

TH

LES SONT 

LES SONT 

NE 

NE 

SE UN MUR OU 

UN MUR OU 

IR LES

S ET LES CODES DU 

ES DU 

ACCORDER 

ACCORDER 

À

À

 LA 

 LA 

À

À

NÉE D’UN AUTRE APPAREIL.

E D’UN AUTRE APPARE

MBUSTIBLE:

BLE:

 POUR USAGE

 POUR USAGE 

A

VEC LE BOIS SEULEMENT. 

IS SEULEMENT. 

N’UTILISEZ PAS DE CHENET OU NE

AS DE CHENET OU N

SURÉLEVEZ PAS LE BOIS. 

SURÉLEVEZ PAS LE BOIS. 

PRÉPAREZ LE FEU DIRECTEM

PRÉPAREZ LE FEU DIRE

SUR L’

UR L’

ÂTRE.

ÂTRE.

AVERTISSEMENT: 

AVERTISSEMEN

RISQU

RISQ

SA

D’

D’

ÉCHAPPEMENT DE 

ÉCHAPPEMENT DE

TENIR LA PORTE FE

TENIR LA PORTE

LORSQUE LE PO

ORSQUE LE P

REMPLACEZ 

REMPLACEZ 

VITRE EN C

VITRE EN C

E SUR

PP

M

RE EXI

RE EX

LEEEE

ALCOVE

ALCOVE

A"

B"

B"

EEEEEEE

LE

LE

LLE

LE

LE

LL

C

SIDE W

A

LL

 (M/L)

E W

A

LL

 (M/L

AMPLE

BE INSTALLED ON A COMBUSTIBLE

E INSTALLED ON A COMBUSTIBLE

PROVED NON-COMBUSTIBLE HEA

ROVED NON-COMBUSTIBLE HEA

0mm) BEYOND THE STOVE SIDES A

BEYOND THE STOVE SIDES

HE FRONT.

E FRON

EST INSTALL

EST INSTALL

É SUR UN PLANCHER C

SUR UN PLANCHER C

BASE DE PROTECTION INCOMBUSTIB

BASE DE PROTECTION INCOMBUSTIB

TÉS ET L’AM

TÉS ET L’AM

ÉRE DU 

ÉRE DU 

PO

ÊLE DE 8” (20

DE 8” (2

mm) SUR LE DEVANT.

mm) SUR LE DEVANT.

INIMUM CLEARANCE TO COMBUS

UM CLEARANCE T

P

CHIMNEY CONNECTOR / 

CHIMNEY CONNECTO

D

ÉGAGE

PP

COMBUSTIBLES

COMBUSTIBLES

 AVEC RACCORD

 AVEC R

MP

Summary of Contents for 1100PL

Page 1: ...al building or fire authority and follow their guidelines Operate only with the door tightly closed Burn wood behind the log retainer directly on the firebricks Do not use an elevated grate or otherwi...

Page 2: ...TION 1100PL 1400PL 19 5 2 DOOR REMOVAL INSTALLATION 1100PL 1400PL 19 5 3 1100C 1400C DOOR REMOVAL INSTALLATION 19 5 4 1400C CAST LID LEVELLING 20 5 5 DOOR HANDLE INSTALLATION 20 5 6 BRICKS AND BAFFLES...

Page 3: ...OVERVIEW Legs see LEG INSTAL LATION section Blower see OPTIONAL BLOWER KIT INSTAL LATION section Ash drawer see OPTIONAL ASH DRAWER KIT section Door see DOOR AND HANDLE INSTALLATION section Draft see...

Page 4: ...o circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a seperate solid fuel burning appliance Do not operate the appliance with the gl...

Page 5: ...4 12 3 4 14 HEIGHT LEG MODEL E 32 28 1 2 32 28 1 2 CHAMBER D W H 13 1 2x18x12 13 1 2x18x12 18x18x12 18x18x12 CAPACITY 1 7ft3 1 7ft3 2 25ft3 2 25ft3 APPROX AREA HEATED 600 1500 ft2 600 1500 ft2 1000 20...

Page 6: ...re DURING THIS PROCESS DO NOT OVERFIRE THE APPLIANCE REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED 4 7 ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN...

Page 7: ...stion chamber is lined with high temperature firebrick on 2 sides the back and across the bottom with a layer of fibre baffles at the top to maintain a high temperature in the combustion chamber so th...

Page 8: ...MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION RENSEIGNEZ VOUS AUPR S DESAUTORIT S LOCALES DU B TIMENT ET DU SERVICE DES INCENDIESAU SUJET...

Page 9: ...FEET CEILING OF ENCLOSURE TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT WARNING BACK WALL B SIDE WALL A BACK WALL C SIDE WALL F D E E PARALLEL CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR 1100PL...

Page 10: ...xhaust house air The house has tight fitting windows and or is equipped with a well sealed vapour barrier 3 5 1 Connection from the appliance s air intake to the outside is mandatory in mobile homes o...

Page 11: ...licone to maintain a vapour barrier at the chimney and outside air pipe penetrations DO NOT INSTALL IN SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAI...

Page 12: ...E THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRE STRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM...

Page 13: ...MISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIGHT ABOVE THE STOVE ALL HORIZONTAL SMOK...

Page 14: ...to 10 In the case of vertical installation the total length of the connector can be longer and connected without problem to the chimney at the ceiling level There should never be more than two 90 elb...

Page 15: ...ney must extend at least 3 feet above its point of contact with the roof and at least 2 feet higher than any wall roof building or obstacle within 10 feet horizontally 59 1A 3 FT MIN 3 FT MIN 3 FT MIN...

Page 16: ...hat the chimney passes through If your chimney system is enclosed within the attic area a rafter radiation shield is required C Hold a plumb bob from the underside of the roof to determine where the o...

Page 17: ...or any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall...

Page 18: ...you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must normally be lined with fire clay bricks metal or clay...

Page 19: ...n all four legs Do not pivot appliance up on its legs as this could result in damage to the legs 5 0 FINISHING 5 2 DOOR REMOVAL INSTALLATION 1100PL 1400PL PINS 5 2 1 Pivot the door open and lift up to...

Page 20: ...E DOOR WHEN THE APPLIANCE IS HOT WARNING DOOR HANDLE NUT DOOR HANDLE LATCH LOCK WASHER DOOR SPACER SPRING WASHER FRONT VIEW NOTE Position of door handle latch NOTE DOOR MAY NOT BE AS ILLUSTRATED 5 4 1...

Page 21: ...the rear of the firebox leaving a minimum of a 1 gap along the front This will allow the flue gases to escape the firebox 5 6 3 Install the 4 bricks along the front NOTE Do not operate if baffle and...

Page 22: ...ows for convenient removal of excess ash This kit can be purchased through your authorized dealer distributor 6 0 OPTIONAL KIT INSTALLATIONS IMPROPER DISPOSAL OF ASHES RESULT IN FIRES DO NOT DISCARD A...

Page 23: ...liance will perform normally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline crac...

Page 24: ...ppliance ensure that the two upper fibre baffles are not lifted up and off their ledge For maximum efficiency when the appliance is thoroughly hot load it fully to the top of the door opening and burn...

Page 25: ...installed appliance should not smoke If yours does check the following Has the chimney had time to get hot Is the smoke passage blocked anywhere in the appliance chimney connector or chimney Is the r...

Page 26: ...CREOSOTE FORMATION AND REMOVAL 8 1 1 APPLIANCES WITHOUT ASH PAN Since some models will not have ash pans shovel some ashes out through the door into a metal container with a tight fitting lid The ashe...

Page 27: ...ct the chimney for stress and cracks prior to lighting an other fire Also check combustibles around the chimney and the roof A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM THIS DAMAGE CAN O...

Page 28: ...or frame down careful not to scratch the paint 8 5 2 Remove the screws and brackets holding the glass in place Remove all broken glass 8 5 3 Wrap the edges of the new glass with a U shaped strip of fi...

Page 29: ...ntil the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3 HOT GLASS WILL CAUSE BURNS DO NOT TO...

Page 30: ...the wood will roll onto the glass DO S Build a hot fire Use only dry wood Several pieces of medium sized wood are better than a few big pieces Clean chimney regularly Refuel frequently using medium si...

Page 31: ...5 W090 0005 W090 0005 BRICK 4 RIGHT 6 W090 0016 W090 0016 W090 0016 W090 0016 BRICK 5 7 W090 0017 W090 0017 W090 0017 W090 0017 BRICK 6 8 W090 0018 W090 0018 W090 0018 W090 0018 BRICK 8 9 W090 0019 W0...

Page 32: ...T 34 115KT 115KT 115KT 115KT OUTSIDE AIR KIT 35 N A W470 0020 N A W470 0020 MAJOLICA BROWN ENAMEL TOUCH UP AND BRUSH 36 EP62 1 EP62 1 EP62 1 EP62 1 VARIABLE SPEED BLOWER 37 EPA RK N A EPA RK N A SOLID...

Page 33: ...kage Inspect chimney Smokes when door is open Cold air blockage Burn a piece of paper to establish a draft Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are pos...

Page 34: ...ed NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product NAPOLEON will not be responsible for over firing downd...

Page 35: ...35 W415 0762 A 07 19 10 43 1 12 0 SERVICE HISTORY...

Page 36: ...36 W415 0762 A 07 19 10 44 1 13 0 NOTES...