13.0 CONVERSIONS
13.1 HIGH ALTITUDE CONVERSION
H18.1.2
In Canada and the United States, this furnace is certi
fi
ed to 2000 feet (610m) on natural gas only. In the
United States of America above 2000 feet, the modi
fi
cations for high altitude are based on a 4% reduction of
input capacity for every 1000 feet (305m) above sea level. In Canada units above 2000 feet (610m) will need
to be derated 10%. Table 6 illustrates the impact of altitude for selected elevations. Consult with local fuel
suppliers or authorities to determine local regulations or customs.
Input
K/Btu/hr
ALTITUDE
ORIFICE SIZE (DMS)
NATURAL
40/60/80
100/120
0-2000 (0-610 m)
45
2000-3000 (610-914 m)
3000-4000 (914-1219 m)
4000-5000 (1219-1524 m)
5000-5400 (1524-1646 m)
5400-6000 (1646-1829 m)
51
6000-7000 (1829-2134 m)
52
7000-8000 (2134-2438 m)
53
8000-9000 (2438-2743 m)
54
9000-10000 (2743-3048 m)
55
TABLE 6 - HIGH ALTITUDE SPECIFICATIONS
H12.8.6
WHITE-RODGERS 36G54 TWO STAGE GAS VALVE
1. Turn off the gas and electrical supply to the furnace.
2. Back inlet pressure test screw (inlet pressure boss, see FIGURE 31) counterclockwise out one turn
maximum, with a 3/32” Allen wrench. Attach a hose and calibrated U-tube or digital manometer to the inlet
pressure boss. Hose should overlap boss 3/8”. The manometer must have a scale range of at least 0” to
15” of water column.
3. Turn ON the gas and electrical supply and operate the furnace and all other gas consuming appliances on
the same gas supply line. Using a leak detection solution, check for leaks around the gas valve/manifold
connection and the burner ori
fi
ces. Repair any leaks before continuing.
4. Measure furnace gas inlet pressure with burners
fi
ring. Inlet pressure must be within the range speci
fi
ed
on the furnace rating plate. 5-7” w.c. (Natural Gas).
If the inlet pressure differs from the rating plate, make the necessary adjustments to pressure regulator,
gas piping size, etc. and/or consult with local gas utility.
5. Turn off gas and electrical supply to furnace, remove the manometer hose from the inlet pressure tap
boss, and tighten the inlet pressure tap screw using the 3/32” Allen wrench. (Clockwise, 7 in-lb minimum).
6. Turn on the gas supply and electrical power to the furnace.
13.2 NATURAL TO LP GAS
13.3 CHECKING THE INLET GAS PRESSURE
This unit is certi
fi
ed for
natural gas only
.
Summary of Contents for 9600E E-STAR Series
Page 27: ...W415 2159 D 11 24 17 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 2159 D 11 24 17 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 57: ...W415 2159 D 11 24 17 57 IOM 23 0 SERVICE HISTORY 43 1...
Page 58: ...W415 2159 D 11 24 17 58 IOM IOM 24 0 NOTES 44 1...
Page 74: ...6 0 NOTES 44 1 W415 2159 D 11 24 17 UM 74...