W415-0616 / E / 10.08.08
12
2.3 SPECIFICATIONS
Electrical Rating
115 volts, 3.6 Amps, 60hz
Watts during Start-Up Sequence
400 (approximately)
Watts during Operation
180 (approximately)
NPS40 Width
22 3/8"
NPS40 height
30 1/2"
NPS40 depth
26 5/8"
Weight
210 Pounds
Exhaust Collar
3"
Intake Collar
2"
NPS40 hopper Cap.
55 Pounds
NPI40 hopper Cap.
45 Pounds
EPA
Exempt
burn Rate**
1.0 to 5.0 (Pounds Per hour)
bTU/h**
8500 to 42500
minimum Fireplace Opening Size
Front: 22 1/2* W x 20 5/8 h x 14 1/4 d
back: 20 3/8 W
* In order to install flashing flush to finished wall and centered within the opening the front opening of the fireplace or enclo
-
sure must be 32 5/8" wide.
2.5 EPA COmPLIANCE
This heater is EPA exempt from Phase II
requirements, but has been tested for emissions
using EPA test methods by Warnock Hersey.
We recommend that our pellet hearth
products be installed and serviced by
professionals who are certified in the
U.S. by the National Fireplace Institute
(NFI) as NFI Pellet Specialists
or who are certified in Canada
by Wood Energy Technical
Training (WETT).
www.wettinc.ca
TP - PEllET SAFETY FEATURES
TP - PEllET EPA
2.4 SAFETY FEATURES
HIGH LIMIT SWITCH:
Your heater is equipped with a high limit switch. In the event that the temperature of the heater
approaches an unsafe operating temperature, this switch will shut down the pellet feed, which will eventually shut down the
unit. If this happens, it is important to find out why the unit overheated. Contact your local dealer.
LOW LIMIT SWITCH:
This switch will automatically shut down the heater if the fire goes out.
HOPPER DOOR INTERLOCK:
Your heater is equipped with a micro switch in the hopper assembly that shuts-off the
auger when the hopper door is opened. Closing the door switches the auger back on, allowing pellets to feed again.
BLOWER OVER-RIDE SWITCH:
Your heater is equipped with a convection blower that circulates hot air into your room.
This switch will automatically turn the blower on, when the temperature at the back of the fire box reaches a certain
temperature. The blower can cycle from your desired setting to maximum speed depending on the feed rate. When the
heater cools back down, the blower will return to the initial setting.
VACUUM SWITCH:
This switch will sense lack of air flow through the heater and shut down the pellet feed. This lack of
flow could be caused by a blocked vent.
POWER FAILURE:
In the event of a power failure, the heater will shut down. Once power is restored, the heater will
re-start, unless the convection air temperature has gone above the high limit switch setting. If this happens, contact your
local dealer.
Summary of Contents for Auburn NPS40
Page 1: ...W415 0616 E 10 08 08 1 W415 0616 E 10 08 08 10 00 ...
Page 35: ...W415 0616 E 10 08 08 35 10 0 Normal operating sounds TP OPERATING SOUNDS_PELLET Figure 10 0 ...
Page 40: ...W415 0616 E 10 08 08 40 12 1 Common replacement parts ...
Page 42: ...W415 0616 E 10 08 08 42 69 28 38 70 41 40 53 54 75 71 69 72 12 3 Npi40 replacement parts ...
Page 48: ...W415 0616 E 10 08 08 48 NOTES 15 0 notes TP NOTES ...