Air Shutter Openings

LP

1/16”

NG

1/32”

This appliance has an air shutter that has been factory set open according 
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more 
yellow flame, but can lead to carboning. Opening the air shutter will cause a 
more blue flame, but can cause flame lifting from the burner ports. The 
flame may not appear yellow immediately; allow 15 to 30 minutes for the 
final flame color to be established. 

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED 
INSTALLER!

AIR 
SHUTTER 
OPENING

VENTURI
BURNER

ORIFICE

49.1

Tear the embers into pieces and place along the burner ports covering all of the burner.  Care should be taken 
to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow. The 
ember material will only glow when exposed to direct fl ame; however, care should be taken to not block the 
burner ports. 
Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Phazer

TM

 

logs glow when exposed to direct fl ame. Use only certifi ed "glowing embers" and Phazer

TM

 logs available from 

your Napoleon® dealer.

2.5 GLOWING 

EMBERS

It’s important to periodically perform a visual check of the pilot and burner 
fl ames. Compare them to the illustrations provided. If any fl ames appear abnor-
mal call a service person.

54.3

3.0 ADJUSTMENT

3.1 FLAME 

CHARACTERISTICS

3.2 VENTURI 

ADJUSTMENT