background image

It’s important to periodically perform a visual check of 

the pilot and burner flames. Compare them to the 

illustration provided. If any flames appear abnormal, 

call a service person.

ADD IMAGE 

HERE

36.1

3.1  flame characteristics

3.2  venturi adjustment

VENTURI ADJUSTMENT CHART

NG

3/16” (4.8mm)

P

7/16” (11mm) 

This appliance has an air shutter that has been factory set open according to 

the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more 

yellow flame, but can lead to carbonization. Opening the air shutter will cause 

a more blue flame, but can cause flame lifting from the burner ports. The flame 

may not appear yellow immediately; allow 15 to 30 minutes for the final flame 

colour to be established. 

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED 

INSTALLER!  

AIR 

SHUTTER 

OPENING

VENTURI

BURNER

ORIFICE

33.1

It is important that the orifice is securely inserted into the venturi.

note:

W415-0808 / E / 05.11.18

EN

6

  

installation

4.0  replacements

3.0  adjustment

!

WARNING

26.1

•  Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved 

with this appliance may result in property damage or personal injury.

Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can 

be ordered through your Authorized dealer / distributor. 

For warranty replacement parts, a photocopy of the original invoice will be required to honour the 

claim.

When ordering replacement parts always give the following information:

•  Model & Serial Number of appliance

•  Installation date of appliance

•  Part number

•  Description of part

•  Finish

Parts, part numbers, and availability are subject to change without notice.
Parts identifi ed as stocked will be delivered within 2 to 5 business days for most delivery 

destinations.
Parts not identifi ed as stocked will be delivered within a 2 to 4 week period, for most cases.
Parts identifi ed as ‘SO’ are special order and can take up to 90 days for delivery.

Summary of Contents for B81NS-1

Page 1: ...in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and ser...

Page 2: ...allation 4 2 6 burner cover installation 4 2 7 rock installation 5 3 0 adjustment 6 3 1 flame characteristics 6 3 2 venturi adjustment 6 4 0 replacements 6 4 1 overview 7 2 1 access panel 2 2 burner a...

Page 3: ...trol In the event the lamps or lens need replacing follow the instructions below A Shut off breaker at main power supply B Remove the four screws that secure the lens frame to the firebox sides This f...

Page 4: ...er cover as shown Secure to the burner base with the screws provided and repeat on other side Porcelain wire shields sit on the cover plates as illustrated A Lower the burner cover down onto the burne...

Page 5: ...ports C Place a few rocks randomly between the other rocks Ensure not to cover burner ports D Position the remaining rocks randomly Ensure not to cover burner ports E Repeat on other side WARNING Rea...

Page 6: ...inserted into the venturi note W415 0808 E 05 11 18 EN 6 installation 4 0 replacements 3 0 adjustment WARNING 26 1 Failure to position the parts in accordance with this manual or failure to use only...

Page 7: ...assembly P 04 24 18 A W750 0335 Electrode W750 0336 Flame sensor W100 0113 8 13 14 9 10 11 12 15 8 W456 0034 Inside burner orifice 34 NG W456 0054 Inside burner orifice 54 P 1 2 3 4 5 14 15 12 10 11...

Page 8: ...ORT PRODUCTS 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA...

Page 9: ...ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement avec le type d...

Page 10: ...du br leur la base de la chambre de combustion l aide des vis fournies en vous assurant que l assemblage de veilleuse est plac du c t de l ouverture d acc s de la soupape Ensemble du br leur Assembla...

Page 11: ...2 3 raccords 2 4 installation de la lumi re de veille TUBE DE VENTURI INJECTEUR RACCORDS DE GAZ RACCORDS DE VEILLEUSE POINTS BR LEUR PRIMAIRE LECTRODE DE VEILLEUSE FILS D LECTRODE DE VEILLEUSE Le mod...

Page 12: ...qu illustr Fixez les la base du br leur l aide des vis fournies et r p tez de l autre c t Les protecteurs de fils en porcelaine reposent sur les plaques de recouvrement tel qu illustr A Installez le c...

Page 13: ...es quelques roches de fa on al atoire entre les autres roches en vous assurant de ne pas couvrir les orifices du br leur E Placez les roches qui reste de fa on al atoire en vous assurant de ne pas cou...

Page 14: ...s le venturi note AVERTISSEMENT 26 1 Omettre de positionner les pi ces conform ment ce manuel ou d utiliser uniquement des pi ces sp cifiquement approuv es pour cet appareil peut causer des dommages m...

Page 15: ...ecteur de la veilleuse inf rieure 34 GN W456 0054 Injecteur de la veilleuse inf rieure 54 P 1 2 3 4 5 14 15 12 10 11 6 7 8 9 W456 0034 Injecteur de la veilleuse ext rieure 34 GN W456 0052 Injecteur de...

Page 16: ...ON DE PRODUITS DE CONFORT 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden...

Reviews: