(4) AA
Batteries
7.1 general transmitter layout
7.2 initializing the transmitter / battery holder for the first time
A.
Install the 4 AA batteries into the Proflame 2 battery holder, note the polarity of the batteries and insert as
indicated on the cover (+/-).
B.
Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).
C.
Press the reset/programming button, use a small object such as a paper clip in order to reach the button
marked PRG, as shown in the illustration below.
D.
The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.
E.
Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ON
button, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.
TRANSMITTER
RESET/PROGRAM
BUTTON (PRG)
BATTERY HOLDER
SLIDER SWITCH
Low battery alarm
Key Lock
Room
Temperature
Light
Flame ON
Blower
Transmission
CPI mode
Transmitter is optional with this model.
note:
The initializing process must be completed within 10 seconds of pressing the reset / program button (PRG).
note:
operation
EN
W415-2207 /
C
/
08.23.18
33