1.0 general information
For elevations between 2,000ft (610m) and 4,500ft (1372m) above sea level, this appliance must be de-rated by 10%
using the certifi ed high altitude kit. When the appliance is installed at elevations above 4,500ft (1372m), and in the absence
of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m).
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certifi ed kit is used.
The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not
be removed from the cord plug.
This appliance is approved for closet or recessed installations, as well as for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile home installations. The natural gas model can be installed
in a mobile home that is permanently positioned on its site and fueled with natural gas.
note:
The protective wrap on plated parts is best removed when the assembly is at room temperature but
this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and effi ciencies
GDS25-1
NG
P
Altitude (FT)
0-2,000
Max. Input (BTU/HR)
24,500
Max. Output (BTU/HR)
19,000
16,000
Min. Inlet Gas Supply Pressure
4.5" Water Column (11mb)
11" Water Column (27mb)
Max. Inlet Gas Supply Pressure
13" Water Column (17mb)
13" Water Column (32mb)
Manifold Pressure (Under Flow Conditions)
3.5" Water Column (9mb)
10" Water Column (25mb)
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must
be installed.