W415-1789 / C / 01.29.19
EN
10
4.0 exterior installation
DHC™ Plus
exterior installation is the simplest installation option. It is installed on the exterior wall of the appli-
ance enclosure.
• DHCP-BK
• DHCP-EK
4.1
exterior installation overview
GLASS GUARD
LVX38 illustrated
View of Opposite
Exterior Wall
Maintain
distance to
combustibles.
Interior
Exterior
Appliance
Enclosure
Air
Damper
Assembly
Blower
Housing
Assembly
Wall
Flashing
Decorative
Cover
Exterior
Housing
Assembly
note:
Diagram is for illustrative purposes only. Installation must comply with all local codes.
note:
MUST have air outlet opening.
Appliance
Vent Terminal
(if applicable)
Required:
!
WARNING
• Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
• DO NOT cover or place any items in the
Dynamic Heat Control™
air outlet opening. Failure to comply with
these instructions will create a fire hazard.
•
DHC™ Plus CANNOT be mounted directly above or below the appliance vent terminal as this will
cause the system to fail. It MUST be mounted to the left or right of the appliance vent terminal.
• For optimal performance, we recommend installing
DHC™ Plus
within the top 12” (30.5cm) of the enclosure.
However, it MUST be installed above the appliance.
• The minimum height requirement above the appliance will vary depending on the appliance size. See “minimum
venting requirements” section of your appliance manual for details.
Insulation