Dynamic Heat Control™ installation
5.0 minimum framing dimensions
minimum framing dimensions
For heavier finishing materials such as marble, we recommend adding extra support to the frame. Ensure there is
adequate floor support for the appliance and finishing material.
note:
!
WARNING
• Risk of fire!
• In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance body, it is
recommended that the walls of the appliance enclosure be “finished” (i.e. drywall / sheetrock), as you would finish any
other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.
• Do not notch the framing around the appliance stand offs. Failure to maintain air space clearance may cause over heating
and fire. Prevent contact with sagging or loose insulation or framing and other combustible materials. Block opening into
the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured.
• Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
When using optional finishing accessories, the framing dimensions and finishing materials may differ from what is out-
lined in the section below; refer to the leaflet instructions supplied in the accessory kit for specific framing and finishing
specifications.
note:
Do not put objects in front
of the appliance (minimum
distance of 4 feet)
F
G
F
H
I
E
LV38-1
LV50-2
LV62
LV74
E
20 1/8” (51.1cm)
20 1/8” (51.1cm)
20 1/8” (51.1cm)
20 1/8” (51.1cm)
F
53 13/16” (136.7cm)
65 13/16” (167.2cm)
77 13/16” (197.6cm)
89 13/16” (228.1cm)
G
63 3/4” (162cm)
72 1/4” (183.5cm)
80 11/16” (205cm)
89 1/4” (226.6cm )
H
18 3/16” (46.2cm)
18 3/16” (46.2cm)
18 3/16” (46.2cm)
18 3/16” (46.2cm)
I
90 3/16” (229cm)
102 3/16” (259.5cm)
114 1/8” (289.9cm)
126 1/8” (320.4cm)
1” (2.54cm) min.
6” (15.2cm) min.