EN
W415-1739 / C / 08.03.17
21
finish framing - after appliance installation
9.0 fastener placement restriction
1 1/2”
8”
2”
Gas V
alve
No fasteners permitted with greater than 3/4”
penetration into appliance.
No fasteners permitted.
When securing non-combustibles, we suggest using high temperature construction adhesive within 2” (5.08cm)
above and to the sides from the appliance opening and 8” (20.3cm) below the appliance opening.
DO NOT
SCREW IN THE RESTRICTED AREA AS THIS COULD DAMAGE THE INTERNAL COMPONENTS OF THE
APPLIANCE THAT CAN CAUSE INJURY OR DEATH
.
This applies to both single-sided and see-thru appliances.
Maximum screw length to be used outside the restricted screw area is 3/4” greater than finishing material
thickness.(i.e. no fastener permitted that penetrates the appliance more than 3/4”
6”