EN
W415-1789 / C / 01.29.19
5
installation planning
The
DHC™ Plus
system uses a high performance fan to move unwanted heat outside. Similar to a bathroom fan
or stove range hood, the use of a fan to move air results in sound.
note:
Consider blower kit location carefully as the air flow sound from the blower is more apparent the closer it is to the
appliance and customer. This is particularly important if using the fan to transfer heat inside a home.
1.4
sound considerations
Depending on the installation type,
DHC™ Plus
requires the use of ducting that is not supplied:
Exterior Installation
• N/A
Remote Exterior Installation
• 6” steel rigid venting between appliance enclosure and
DHC™ Plus
blower kit
Remote Inline Installation
• 6” steel ducting between appliance enclosure and
DHC™ Plus
blower kit
• 6” steel rigid venting between
DHC™ Plus
blower kit and hot air exhaust assembly
1.5
venting & ducting
1
3
4
2
2
3
1
#10 Thread, RH
29/64”
1/8”
1-1/2”
Quadrex Drive
#9-14 Thread, RH
Hex
0.348”
Ref.
Description
Ref.
Description
1
Hardware kit
3
Exterior housing assembly
2
Decorative cover
4
Wall flashing
1.3.2 DHCP-HK
Ref.
Description
Ref.
Description
1
Hardware kit
3
Hot air exhaust assembly
2
Wall flashing
1.5.1 DHCP-EK
Always check local codes before installing the
DHC™ Plus
system.
note: