6.0 MAINTENANCE

!

WARNING

PREPARATION FOR MAINTENANCE

ALWAYS DISCONNECT THE POWER AND ALLOW THE ELECTRIC APPLIANCE TO COOL BEFORE 

PERFORMING ANY CLEANING, MAINTENANCE OR RELOCATION OF THIS ELECTRIC APPLIANCE. 

TURN CONTROLS TO OFF AND REMOVE PLUG FROM OUTLET OR TURN OFF THE HOUSE 

CIRCUIT BREAKER TO ELECTRIC APPLIANCE RECEPTACLE.

DO NOT INSTALL REPLACEMENT LAMPS THAT EXCEED SPECIFIED MAXIMUM WATTS.

THE LED BULBS IN YOUR APPLIANCE CAN BECOME EXTREMELY HOT. ALLOW AT LEAST 10 

MINUTES BETWEEN TURNING OFF THE APPLIANCE AND REMOVING THE BULBS TO AVOID 

ACCIDENTAL BURNS.

6.1  REMOTE BATTERY INSTALLATION

1.  To replace the existing battery remove the 

battery holder. 

2.  To remove the battery holder turn remote onto 

front side and press the left side leaver towards 
the center while pulling the battery holder out 
using the slot provided.

3.  Replace existing battery, type CR 2025, with a 

new battery and reinstall the battery holder into 
the remote by sliding it into position, as shown.

4.  Battery holder is secure into the remote control 

when a "CLICKING" noise is heard.

REMOTE

(REAR SIDE)

BATTERY HOLDER

BATTERY (CR 2025)

Summary of Contents for EFC32H

Page 1: ...replaces com ask napoleonproducts com SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injur...

Page 2: ...COMBUSTIBLES AND MANTEL 7 3 2 INSTALLING THE APPLIANCE ON A WALL 8 3 3 RECESSED INSTALLATION 9 3 3 1 MINIMUM CLEARANCE TO COMBUSTIBLES 9 3 3 2 FRAMING 10 4 0 FINISHING 11 4 1 GLASS EMBER INSTALLATION...

Page 3: ...t from carpeting bedding material etc The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids Under no circumstances should this appli...

Page 4: ...2mm 23 1 4 590 6mm 3 3 4 95 3mm 20 1 4 517 5mm 26 3 8 669 9mm 1 1 2 38 1mm 29 1 8 739 8mm EFC32H 32 1 4 819 2mm 23 1 4 590 6mm 4 7 8 123 8mm 20 1 4 517 5mm 26 3 8 669 9mm 2 50 8mm 29 1 8 739 8mm EFL4...

Page 5: ...THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY AND OR PROPERTY DAMAGE ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE DO NOT USE IT IN AREAS WHERE GASOLINE...

Page 6: ...ING INSTALLATION AND MAINTENANCE TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION THE ELECTRIC APPLIANCE MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION LOCALIZED OVERHEATING COUL...

Page 7: ...ON AGAINST THE APPLIANCE THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANC...

Page 8: ...hen mount the bracket onto the wall using the four supplied screws This bracket MUST have the hooks facing upward and be level NOTE It is strongly recommended that the mounting bracket be screwed into...

Page 9: ...ately secured C Use distance A and mark out the location for the second bracket D Mount the bracket onto the wall using the four supplied screws The bracket MUST have the hooks facing upward and level...

Page 10: ...the front glass to the appliance refer to the GLASS FRONT INSTALLATION section NOTE In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance body...

Page 11: ...CANNOT BE COVERED IN ANY CIRCUMSTANCES Shoulder Screw 4 1 GLASS EMBER INSTALLATION Glass front must be removed and the appliance must be mounted in its final location before the glass embers are inst...

Page 12: ...the icons will illuminate and then the icons will darken G To activate the timer control press the timer button the icon will illuminate and the time will appear on the LED display To choose the desi...

Page 13: ...tting Every time the flame is initiated it will start at the brightest level F To begin the thermostat function press the thermostat button the icon on the control panel will illuminate there are 5 se...

Page 14: ...E EXTREMELY HOT ALLOW AT LEAST 10 MINUTES BETWEEN TURNING OFF THE APPLIANCE AND REMOVING THE BULBS TO AVOID ACCIDENTAL BURNS 6 1 REMOTE BATTERY INSTALLATION 1 To replace the existing battery remove th...

Page 15: ...70 NATIONAL ELECTRIC CODE in the United States A Remove the cover plate from the right side of the appliance by removing the two screws as shown in Figure 1 B Remove the wire connectors and strain rel...

Page 16: ...W415 1139 C 05 14 13 16 EN 7 0 WIRING DIAGRAM WARNING ENSURE ALL POWER IS TURNED OFF BEFORE HARD WIRING THIS APPLIANCE CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR...

Page 17: ...HICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER 41 1 FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WIT...

Page 18: ...W415 1139 C 05 14 13 18 EN 1 3 6 2 1 6 1 4 6 8 7 9 3 5 EFL32H EFL60H EFL48H EFL72H 3 3 3 1 1 1 6 6 6 2 2 2 2 SIMILAR ON ALL MODELS EFC32H...

Page 19: ...ries Replace batteries in remote control TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE SYMPTOM PROBL...

Page 20: ...appliance brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or...