W415-3006 / A / 05.27.21
EN
14
framing
4.2 nailing tabs
15.00"
28.25"
1.50"
- NO FASTENERS PERMITTED
- PAS DE FIXATIONS PERMISES
- FASTENERS PERMITTED AREA
- FIXATIONS AUTORISÉES ZONE
5.02"
3.50"
3.00"
16.50"
5.75"
To install the appliance face flush with the finished surface, position the framework to accomodate the thickness of
the finished surface. Screw the nailing tab to either side of the appliance and secure to the 2 x 4 steel framing. The
tabs will faciliate the installation of either a 1/2” (13mm) or 3/4” (19mm) finished surface thickness.
4.3 clearance to combustible
!
WARNING
• Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
Minimum Clearance To Combustibles
Clearance
Dimension
A
From Ground or other surface
6” (152 mm)
B
From Sides
6” (152 mm)
C
From Ceiling
36” (915 mm)
D
Alcove Width
60” (1524 mm) Minimum
E
Alcove Depth
24” (610 mm) Maximum
A
B
C
D
E