36
W415-0663 / C / 03.17.11
7.0 OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must
be electrically connected and grounded in accordance with local codes.
In the absence of local codes, use the current CSA C22.1 Canadian
electrical code in Canada or the ANSI / NFPA 70 National Electrical Code
in the United States.
If the appliance was not previously equipped with a blower:
Route a grounded 2-wire, 60hz power cable to the receptacle /
junction box. At this point, it must be strain relieved and insulated.
The three slots on the blower mounting bracket allow ease of adjustment when
attaching the blower. For a quiet running blower, do not allow the assembly to
sit on the firebox base. Slide the vibration reducing pad
(A)
into the clip
(C)
and
up against the threaded stud
(B)
at the other end. The blower must be able to
be positioned entirely onto the pad.
To ease installation of the blower, remove the hinge screen and valve control door
(lower louvres) from the base of the appliance.
Tilt the blower onto its side. Slide it past the controls and into the clip
(C)
.
Secure to the threaded stud using the lock washer and wing nut provided.
Ensure that the blower does not touch the appliance base or the firebox.
black
white
red
VARIABLE
SPEED
SWITCH
BLOWER
THERMAL
SWITCH
SLOTS
ELONGATED
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.