background image

6

WS-415-63 / 11.24.98

Use only Napoleon or Simpson Dura-Vent Model DV-GS venting components. Minimum and maximum vent lengths, for
both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must
be adhered to. For Simpson Dura-Vent, follow the installation procedure provided with the venting components.
When using Napoleon venting components, use only the following vent kits: WALL TERMINAL KIT 

GD175 

(7-1/2' of

venting included), or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT

 GD110

, 8/12 TO 12/12 ROOF TERMINAL KIT

 GD111

,

FLAT ROOF TERMINAL KIT

 GD112 

or STOVE PERISCOPE KIT

 GD180 

(for wall penetration below grade)

 

in conjunction

with the appropriate venting components.
These vent kits allow for either horizontal or vertical venting of the stove. 

FIGURES 2, 3, & 4

. The maximum number of 4"

flexible connections is two horizontally or three vertically (excluding the stove and the air terminal connections).

Use an adjustable pipe as the final length of rigid piping to the stove for ease of installation.

For optimum flame appearance and stove performance, keep the vent length and number of elbows to a minimum. On
extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after lighting. The air terminal must
remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and
undamaged.

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONTAL RUN IS 34 INCHES WITH A 90

AL RUN IS 34 INCHES WITH A 90

AL RUN IS 34 INCHES WITH A 90

AL RUN IS 34 INCHES WITH A 90

AL RUN IS 34 INCHES WITH A 90

o

o

o

o

o

 ELBOW LOCA

 ELBOW LOCA

 ELBOW LOCA

 ELBOW LOCA

 ELBOW LOCATED

TED

TED

TED

TED

29" ABOVE THE STOVE.

29" ABOVE THE STOVE.

29" ABOVE THE STOVE.

29" ABOVE THE STOVE.

29" ABOVE THE STOVE.

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONT

THE MAXIMUM HORIZONTAL RUN WITH A 57 INCH VERTICAL RISE IMMEDI-

AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI-

AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI-

AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI-

AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI-

A

A

A

A

ATEL

TEL

TEL

TEL

TELY ABOVE THE STOVE IS 20 FEET

Y ABOVE THE STOVE IS 20 FEET

Y ABOVE THE STOVE IS 20 FEET

Y ABOVE THE STOVE IS 20 FEET

Y ABOVE THE STOVE IS 20 FEET.....

IF VERTICAL RISES GREA

IF VERTICAL RISES GREA

IF VERTICAL RISES GREA

IF VERTICAL RISES GREA

IF VERTICAL RISES GREATER THAN 57 INCHES ARE NECESSARY

TER THAN 57 INCHES ARE NECESSARY

TER THAN 57 INCHES ARE NECESSARY

TER THAN 57 INCHES ARE NECESSARY

TER THAN 57 INCHES ARE NECESSARY, THE INCREASED

, THE INCREASED

, THE INCREASED

, THE INCREASED

, THE INCREASED

RISE MUST BE DEDUCTED FROM THE HORIZONT

RISE MUST BE DEDUCTED FROM THE HORIZONT

RISE MUST BE DEDUCTED FROM THE HORIZONT

RISE MUST BE DEDUCTED FROM THE HORIZONT

RISE MUST BE DEDUCTED FROM THE HORIZONTAL RUN.

AL RUN.

AL RUN.

AL RUN.

AL RUN.

When terminating vertically, the minimum vertical rise is 34 inches above the stove and the
maximum vertical rise is 15 feet. 

FIGURE 4.

 

Deviation from the minimum vertical vent length

can create difficulty in burner start-up and/or carboning.

When a horizontal run is introduced, even though the terminal may be vertical, the installation
must be considered 

HORIZONTAL

.

Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. 

FIGURE 5.

When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow. (DO NOT
INCLUDE THE FIRST ELBOW DIRECTLY OFF THE UNIT.)

HORIZONTAL RUN NOT TO
EXCEED VERTICAL RISE

FIGURE 2

FIGURES 3

REQUIRED VER

REQUIRED VER

REQUIRED VER

REQUIRED VER

REQUIRED VERTICAL RISE

TICAL RISE

TICAL RISE

TICAL RISE

TICAL RISE

FROM FIREPLACE TO FIRST

FROM FIREPLACE TO FIRST

FROM FIREPLACE TO FIRST

FROM FIREPLACE TO FIRST

FROM FIREPLACE TO FIRST

ELBOW IN 

ELBOW IN 

ELBOW IN 

ELBOW IN 

ELBOW IN INCHES

INCHES

INCHES

INCHES

INCHES

CALCULA

CALCULA

CALCULA

CALCULA

CALCULATED HORIZONT

TED HORIZONT

TED HORIZONT

TED HORIZONT

TED HORIZONTAL VENT RUN IN 

AL VENT RUN IN 

AL VENT RUN IN 

AL VENT RUN IN 

AL VENT RUN IN FEET

FEET

FEET

FEET

FEET

FIGURE 4

FIGURE 5

Summary of Contents for GDS3700-N

Page 1: ...22 6031 Email ask napoleon on ca Web www napoleon on ca Wolf Steel Ltd RR 1 9 Napoleon Rd Barrie ON Canada L4M 4Y8 705 721 1212 R 2000 Immediately call your gas supplier from a neighbour s phone Follo...

Page 2: ...tical Venting Installation Stove Vent Connection 10 10 10 10 10 GAS INST GAS INST GAS INST GAS INST GAS INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION 11 11 11 11 11 FINISHING FINISHING FINISHIN...

Page 3: ...proval of an authorized company official Labour costs work however requires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to t...

Page 4: ...or the ANSI NFPA 70 1990 NATIONAL ELECTRICAL CODE in the United States The blower power cord must be connected into a properly grounded receptacle The grounding prong must not be removed from the cord...

Page 5: ...ts burners and circulating blower and its passageway in the stove and venting system are kept clean The stove and its venting system should be inspected before use and at least annually by a qualified...

Page 6: ...E IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI AL RUN WITH A 57 INCH VERTICAL RISE IMMEDI A A A A ATEL TEL TE...

Page 7: ...A ALLA ALLA ALLATION EXAMPLE TION EXAMPLE TION EXAMPLE TION EXAMPLE TION EXAMPLE If a first run of 48 inches is required using the First Vent Run chart shows that a 51 inch vertical rise is necessary...

Page 8: ...as illustrated in FIGURE 9 FIGURE9 G Seven feet above public walkways unless fitted with heat shield kit GD301 H One foot below windows that open I One foot from the side of doors and windows that ope...

Page 9: ...12 3 Slip the first section of 7 diameter stove pipe a minimum of 2 over the outer sleeve of the air terminal Secure to the sleeve using 3 screws Seal the joint and screw heads using high temperature...

Page 10: ...INSTALLA ALLA ALLA ALLA ALLA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN OPTIONAL DECORA TION IS COMPLETED AN O...

Page 11: ...ated on the rear wall of the combustion chamber The notch situated at the lower left of the back log should be centered evenly above the pilot assembly FIGURE 21 3 While supporting the back log to pre...

Page 12: ...supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FOR YOUR SAFETY READ BEFORE OPERATING A This fireplace is equip...

Page 13: ...will run for approximately 30 minutes after the stove has been turned off Use of the fan in creases the output of heat 1 Mount the variable speed switch insert the rheostat stem through the 3 8 diame...

Page 14: ...SCOPE TERMINAL KIT GD180 PERISCOPE TERMINAL KIT GD180 PERISCOPE TERMINAL KIT PART PART PART PART PART DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION PART PART PART PART PART DESCRIPTION D...

Page 15: ...15 WS 415 63 11 24 98 included with GD180 included with GD175 I H L O L F F N T I O O P O...

Page 16: ...ooled Allow approximately 60 seconds for the thermocouple to cool Pilot flame is not large enough turn up the pilot flame Pilot flame is not engulfing the thermocouple turn up pilot flame replace pilo...

Page 17: ...moved as required refer to Figure 16 to ensure correct location of storm collars Incorrect installation Main burner goes out pilot goes out REFER TO MAIN BURNER GOES OUT PILOT STAYS ON Thermocouple sh...

Page 18: ...18 WS 415 63 11 24 98 NOTES...

Reviews: