background image

W415-0372 / 02.12.03

9

1.

 The appliance should be inspected before initial use

and inspected and cleaned at least annually by a qualified
field service person.

2.

 Tampering is DANGEROUS and voids all warranties.

Any component that is found to be faulty, must be replaced
with an approved component.

3.

 To obtain proper operation, it is imperative that the burner

flame characteristics are steady, not lifting or floating. Check
the burner flame patterns with the figure below.

4.

 Periodically remove the logs and examine the burner. If

dirty, clean with a soft brush. Also examine the area around
the burner air shutter. Any dirt or foreign material, such as
spider webs or nests, in this area should be removed.
This will ensure long life and trouble free operation. When
the appliance is put back in service, check the burner flame
patterns with the figure above. Reinstall the logs as shown
in the log placement instructions.

5.

 Periodically check the hose connecting the LP gas cylin-

der to ensure it is not damaged in any way.

NOTE:

 Carbon (soot) may build up on the surface of the

logs with heavy use. This is more likely to occur when us-
ing LP gas. The soot should be cleaned off the surface of
the logs periodically to prevent excessive build up. To clean
the logs, be sure the fire is out, the gas supply is turned off
and the logs are cool to the touch.  The soot can then be
brushed off with a dry bristle brush or cloth. Take care while
cleaning the logs as they can become damaged if mis-
handled. Care should be taken to dispose of the soot and
cleaning materials properly. Keep away from clothing and
outdoor furniture.

This listed gas appliance is tested and approved for eleva-
tions from 0 to 4500 feet in Canada and the U.S.

When installing this appliance at an elevation above 4500
feet (in the U.S.), it may be necessary to decrease the input
rating by changing the existing burner orifice to a smaller
size. Input should be reduced four percent (4%) for each
1,000 feet above sea level, unless the heating value of the
gas has been reduced, in which case this general rule will
not apply. To identify the proper orifice size, check with the
local gas utility.

When installing this unit at an elevation above 4,500 feet
(in Canada), check with local authorities.

Consult your local gas utility for assistance in determining
the proper orifice for your location.

MAINTENANCE

HIGH ELEVATION INSTALLATION

During the winter months in cold weather climates, it is
recommended to disconnect the Patioflame and store it in
a cool dry place. Do not store the propane tank inside. For
the remainder of the year, protect and cover your Patioflame
from rain, freezing rain and snow.

Summary of Contents for GPFN

Page 1: ...pours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your build ing...

Page 2: ...or ore installing or ser e installing or ser e installing or ser e installing or ser e installing or servicing this equipment vicing this equipment vicing this equipment vicing this equipment vicing t...

Page 3: ...t pride in their work The burner and valve assembly are leak and test fired at a quality test station Once assembled the complete appliance is thoroughly inspected by a qualified technician before pac...

Page 4: ...e Clothing or other flammable materials should not Clothing or other flammable materials should not Clothing or other flammable materials should not Clothing or other flammable materials should not Cl...

Page 5: ...iling 72 1830 Natural LP Propane Minimum Inlet Pressure 4 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c Model Fuel Max Input Btu Hr GPFN Natural Gas 60 000 GPFP Propane Gas 60 000 INPUT MINI...

Page 6: ...repairs can be made NATURAL GAS LP GAS ENCLOSURES FOR LP GAS SUPPLY SYSTEMS If you build an enclosure for an LP gas cylinder follow these recommended specifications You must also follow local codes E...

Page 7: ...t base log onto burner ensuring stud and bracket fit into hole and notch Base log should sit flat on Patioflame base 2 Place Y end of log 1 into Y notch on the base log 3 Place pocket on log 2 onto th...

Page 8: ...trol valve 2 Place the firestarter near the burner ports on top of the burner Light the firestarter For a Natural Gas unit turn on the ON OFF valve slowly at the unit For a LP unit turn the valve in t...

Page 9: ...build up To clean the logs be sure the fire is out the gas supply is turned off and the logs are cool to the touch The soot can then be brushed off with a dry bristle brush or cloth Take care while c...

Page 10: ...an be ordered through your Napoleon dealer or distributor When ordering replacement parts always give the follow ing information 1 MODEL SERIAL NUMBER OF APPLIANCE 2 INSTALLATION DATE OF APPLIANCE 3 P...

Page 11: ...W415 0372 02 12 03 11...

Page 12: ...W415 0372 02 12 03 12 Wolf Steel Appliance Service History This appliance must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Reviews: