background image

14

W415-0297 / 

Q

 / 

08.23.18

Replacement loose material must be purchased from
the original manufacturer. Application of 
excess loose material may adversely affect the 
performance of the appliance.

Log colours may vary. During the initial use of the 
appliance, the colours will become more uniform as 
colour pigments burn in during the heat activated curing 
process.

Reinstall rod assembly and mesh curtain.

5.1  GRATE AND LOG PLACEMENT

Remove curtain mesh and rod assembly
Remove log carton
Remove grate from the lower control area (stored there when shipped)
Unscrew the 3 screws in the fi rebox, set grate in place and secure using the 3 screws that were just re-

moved.  

Install the one piece log set by aligning the two holes on the bottom of the logs, with the two locating pins in the 

fi rebox. 

NOTE: PHAZER

TM

 logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and 

realistic glowing effect that is different in every installation. Take the time to carefully position the 
glowing embers for a maximum glowing effect.

!

WARNING

LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE 

PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY. DELAYED IGNITION 

AND CARBON / SOOT DISTRIBUTION THROUGHOUT THE LIVING AREA MAY OCCUR.

THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. 

DO NOT PLACE CHARCOAL EMBERS, VERMICULITE OR CHARCOAL LUMPS ON THIS BURNER.

ALL PREVIOUSLY APPLIED LOOSE MATERIAL (GLOWING EMBERS) MUST BE REMOVED PRIOR TO 

REAPPLICATION.

DO NOT CHANGE OR SUBSTITUTE THE GLOWING EMBER MATERIAL PROVIDED WITH THE 

APPLIANCE. IF REPLACING, USE ONLY REPLACEMENT GLOWING EMBERS AVAILABLE FROM 

YOUR LOCAL AUTHORIZED DEALER / DISTRIBUTOR.

FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY EFFECT THE APPLIANCE’S 

PERFORMANCE AND MAY RESULT IN CARBON / SOOT DEPOSITS INSIDE THE APPLIANCE AND ON 

SURROUNDING SURFACES.

76.2B

Summary of Contents for Grandville GVF36-2P

Page 1: ...EFERENCE NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS 1 23B Wolf Steel Ltd 24 Napoleon Rd Barrie ON L4M 0G8 Canada 103 Miller Driv...

Page 2: ...ETERMINING CONFINED OR UNCONFINED SPACE 7 3 3 GAS INSTALLATION 8 3 4 OPTIONAL WALL SWITCH THERMOSTAT 9 3 5 MOBILE HOME INSTALLATION 9 4 0 FRAMING 10 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 11 4 2 MINIMU...

Page 3: ...d hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the ap...

Page 4: ...7 CMR 30 00 upon the sale of the appliance from http www napoleonfireplaces com Webshare installation_manuals mass_requirements pdf WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH EARLY SIGNS OF C...

Page 5: ...on for the appliance is in the center of a building thereby allowing the most efficient use of the heat created The location of windows doors and the traffic flow in the room where the appliance is to...

Page 6: ...TER COLUMN SIT CONTROL 820637 SIT CONTROL 820636 OPERATING PILOT OXYPROTECTOR 8214 OPERATING PILOT OXYPROTECTOR 8404 ABOVE 2 000FT CONSULT LOCAL AUTHORITY HAVING JURISDICTION NOT FOR USE WITH SOLID FU...

Page 7: ...phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and B Weather stripping has been added on openable windows and...

Page 8: ...3 EXAMPLE 2 If in this example a solid door separates Room 1 from Room 2 the volume of Room 2 could not be used In this case the maximum BTU h would be Maximum BTU h 800x1000 16 000 BTU h 50 This woul...

Page 9: ...HEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS S...

Page 10: ...C AND UL763 SHALL BE CONSIDERED NON COMBUSTIBLE MATERIALS MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD COULD RESULT THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT M...

Page 11: ...may occur at or after a minimum distance of 2 away from the side of the appliance Thereafter the depth of any protrusions must be of equal to or less than the distance from the side of the appliance...

Page 12: ...sure space around and above the appliance must be left unobstructed 4 3 MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WIT...

Page 13: ...3 4 or a 1 finished wall thickness The nailing tabs must not be removed nailing tab WARNING RISK OF FIRE NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE THE FRONT OF THE APPLIANCE MUST BE FINISHED...

Page 14: ...lusive to Napoleon Fireplaces provide a unique and realistic glowing effect that is different in every installation Take the time to carefully position the glowing embers for a maximum glowing effect...

Page 15: ...to thin small irregular pieces as only the exposed edges of the fibre hairs will glow NOTE The ember material will only glow when exposed to direct flame however care should be taken to not block the...

Page 16: ...ERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 51 5 Remove the backing of the logo supplied and place on the screen...

Page 17: ...e blower does not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the uni...

Page 18: ...ront of the back log G Turn gas knob counter clockwise to pilot H Depress and hold gas knob while lighting the pilot with the push button ignitor Keep knob fully depressed for one minute then release...

Page 19: ...y allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER AIR SHUTTER OPENING VENTURI BURNER ORIFICE 49 1 AIR SHUTTER OPEN...

Page 20: ...CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance and its venting...

Page 21: ...HERMOPILE 4 W725 0030 NATURAL GAS VALVE 4 W725 0031 PROPANE GAS VALVE 5 W385 0334 NAPOLEON LOGO 6 W750 0112 20FT OF WIRE 7 GL 664 ONE PIECE LOG SET W135 0335 8 W361 0016 GLOWING EMBERS 9 W550 0001 CHA...

Page 22: ...NELS 35 TB336K BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H TEXTURED BLACK 35 TB336AB BEVELLED TRIM KIT 3 COVERS OPENING 37 W X 33 H ANTIQUE BRASS 35 TB336PB BEVELLED TRIM KIT 3 COVERS OPENING 37 W...

Page 23: ...low Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas v...

Page 24: ...and see if pilot flame flutters diminishes or extinguishes especially when main burner ignites Monitor appliance supply working pressure Check if supply piping size is to code Correct all undersized...

Page 25: ...of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applica...

Page 26: ...r plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under t...

Page 27: ...27 W415 0297 Q 08 23 18 13 0 SERVICE HISTORY 43 1...

Page 28: ...28 W415 0297 Q 08 23 18 44 1 14 0 NOTES...

Reviews: