W415-2339 / C / 02.08.21
EN
24
installation
3.3.3 installing natural vent
Follow the instructions of the natural vent manufacturer for chimney installation.
A.
Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B.
Replace the four screws per side to secure the rear panel to
the appliance.
C.
Remove the spill switch bracket from the rear of the adapter.
D.
Gently pull the two wire terminals (located inside the
7" (178mm) fl ue collar at the top of the appliance) out
approximately 8" (203mm).
E.
Bring the wires through the lower hole in the adapter and out
the spill switch opening. To pass the wires through the hole
more easily, temporarily tape the two terminals together.
F.
With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance fl ue collar.
G.
Connect the wire terminals to the spill switch and re-secure the
bracket.
H.
Secure the terminal block into place as shown with the screw
supplied.
I.
Unscrew the wire access cover plate from the rear right hand
side below the fi rebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate.
FOR MILLIVOLT:
Disconnect one of the black on/off switch
wires and attach to the other side of the terminal block.
Connect the remaining wires (1 black - 1 white) with 1/4"
connectors to TP/TH and TH on the gas valve.
FOR ELECTRONIC:
Disconnect
one of the black on/off switch wires
connected to the control module and
connect it to the other side of the
terminal block. Connect the other white
spill switch wire to the control module
(see "wiring diagram (electronic)").
For aesthetics, the adapter has been designed to accept a standard matte black 7" (178mm) stove pipe
and the decorative band (standard with the GS-150KT). Both are available from your local authorized
dealer / distributor.
3.3.4 natural vent
Attach the Natural Vent label (see below) in the control area of the appliance.
SWITCH
SPILL
ADAPTER
COMBUSTION AIR COVER
PLATES AND GASKET
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
MODEL.
ATTACHEZ CET ÉTIQUETTE DANS LA RÉGION DE CONTRÔLE DU FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
W385-0160 / B
NO B-VENT ADAPTER
WIRES (GDS28)
TERMINAL BLOCK
WIRE ACCESS
COVER PLATE
note:
If not converting, the wires are rated for high
temperatures and may remain as is in the
appliance collar.