43
W415-1371 / 09.15.14
EN
HDX52-1
NG
3/8” (9.5mm)
LP
7/16" (11mm)
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
AIR
SHUTTER
OPENING
VENTURI
BURNER
ORIFICE
49.1
9.3 VENTURI
ADJUSTMENT
It’s important to periodically perform a visual check of the pilot and burner
fl
ames. Compare them to the
illustration provided. If any
fl
ames appear abnormal call a service person.
FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSOR
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
3/8” - 1/2”
(9.5mm - 12.7mm)
54.1B
9.4 FLAME
CHARACTERISTICS
MAXIMUM INPUT RATE
NG
55,000 BTU/HR
LP
55,000 BTU/HR