W415-1066 / C / 06.22.12
31
6.6 STArTINg A FIrE
ALwAYs OpERATE THIs AppLIANCE wITH THE FIRE BOx DOOR CLOsED AND LATCHED ExCEpT
DURINg sTART Up AND RE-FUELINg. ALwAYs wEAR gLOvEs TO pREvENT INjURY. DO NOT
LEAvE THE FIRE UNATTENDED wHEN THE DOOR Is UNLATCHED As UNsTABLE wOOD COULD
FALL OUT OF THE FIRE CHAMBER CREATINg A FIRE HAzARD TO YOUR HOME.
NEvER LEAvE CHILDREN UNATTENDED wHEN THERE Is A FIRE BURNINg IN THE AppLIANCE.
DO NOT UsE CHEMICALs OR FLUIDs TO sTART THE FIRE.
DO NOT OpERATE wITH FLUE DRAFT gREATER THAN -0.06” w.C. (-15 pa).
DO NOT sTORE FUEL OR OTHER COMBUsTIBLE MATERIAL wITHIN MARkED INsTALLATION
CLEARANCEs OF THE AppLIANCEs OR wITHIN THE spACE REqUIRED FOR FUELINg, AsH RE-
MOvAL, AND OTHER ROUTINE MAINTENANCE OpERATIONs.
INspECT AND CLEAN FLUEs AND CHIMNEY REgULARLY.
HOT sURFACEs - DO NOT TOUCH DURINg OpERATION.
FREqUENTLY ExAMINE DOOR sEAL/gAskET, REpLACE IF wORN. FAILURE TO sHUT DOOR
TIgHTLY AND IgNORINg LEAkINg gAskET CAN REsULT IN ExTREME OvER FIRINg CONDITIONs.
RIsk OF FIRE OR ExpLOsION - DO NOT BURN gARBAgE, gAsOLINE, DRAIN OIL,
NApHTHA, ENgINE OIL OR OTHER FLAMMABLE LIqUIDs.
6.4 CONTrOL SySTEm - SummEr FAN
• a manual fan switch has been added to the fan speed/limit control located on
the furnace plenum. this will provide air circulation during the summer time
when the furnace is not being used.
ENsURE THE MANUAL swITCH REMAINs pULLED OUT INTO THE "AUTO" pOsITION DURINg THE
HEATINg sEAsON. FAILURE TO COMpLY wITH THIs wILL REsULT IN ExCEssIvE CHILLINg OF
THE ExHAUsT pRODUCTs As THEY pAss THROUgH THE FURNACE FLUE AND THE CHIMNEY sYs-
TEM. THIs CHILLINg wILL REsULT IN THE CONDENsATION OF ExHAUsT pRODUCTs IN THE CHIM-
NEY REsULTINg IN CREOsOTE BUILD Up. THE CREOsOTE BUILD Up sUBsTANTIALLY INCREAsEs
THE RIsk OF A CHIMNEY FIRE.
expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
6.5 OPErATINg SOuNdS ANd SmELLS
When first installed, the furnace brick and metal are cold and must become hot before the appliance will func-
tion well. during the break-in period (the first 2 or 3 fires) create only small, hot fires using kindling; this will
allow the firebrick to cure. do not be alarmed if small hairline cracks develop in the firebrick. this is a normal
occurrence and does not pose a safety hazard. the paint may also smell a little for the first few fires as it
cures and you may wish to open a door or window to alleviate the smell.
there are many different ways to start a fire, review the hints and warnings in this section to ensure the fire is
started properly.
pUsHED IN = MANUAL FAN OpERATION
pULLED OUT = AUTO FAN OpERATION
(plenum temperature dependant)