W415-1013 / C / 11.19.13
27
EN
RIGHT HAND RA PANEL
LEFT HAND RA PANEL
NOTE
Not all oil burner module kits require adapter collar and second
fi
bre gasket.
Check "Manual" Addendum accompanying oil furnace module for speci
fi
c assembly details.
FLANGE GASKET
○
Locate
fl
ange gasket over bolts of oil furnace mounting
fl
ange, prior to placing
bottom front cover up to mounting
fl
ange.
○
Align mounting bolts on
fl
ange align with clearance holes in bottom front panel
when panel loosely
fi
t in
fi
nal position.
○
Correct position of bottom front panel has top
fl
ange of panel over top of
fi
rebox
front
fl
ange and underneath furnace bottom.
○
New bottom front panels in oil furnace module kits.
FURNACE BOTTOM
OIL FURNACE
COMBUSTION CHAMBER
FIREBOX
FRONT
OIL FURNACE
FLUE
STEP #14A
○
When using the Riello Oil Burner (kit # HMFK-OFRF40), the
burner mounting
fl
ange must be located so that the mounting
surface of the
fl
ange is 2.5" (63.5mm) from the
fi
ring end of
the blast tube (combustion head). See diagram.
2.5"
(63.5mm)
STEP #14B
○
Fasten bottom front cover to corner posts using hex head
wildrill screws. Assemble burner,
fl
ange adapter collar (used
with Riello Burner only - kit # HMFK-OFRF40), and gaskets
to oil furnace mounting
fl
ange bolts as per diagram.
○
Attach oil furnace sight glass, gasket, and bracket to bottom
front panel using (2) hex screws.
OIL BURNER
OIL BURNER
MOUNTING
FLANGE
BRASS NUTS
FIBRE
GASKETS
ADAPTER
COLLAR
OIL FURNACE
FLANGE
BOTTOM FRONT
COVER
LEFT HAND RA CONFIG SHOWN
SIGHT GLASS BRACKET
GASKET
SIGHT GLASS