W415-1013 / B / 07.24.13
38
EN
18"
MAX 16" (406mm)
CLEAR
ANCE T
O
COMBUSIBLES
SER
VICE CLEAR
ANCE
24"
(610mm)
CLEAR
ANCE T
O
COMBUSIBLES
SER
VICE CLEAR
ANCE
LEFT HAND RA CONFIGURATION (REAR VIEW)
MINIMUM 40”
(1016mm)
18"
14"
(356mm)
9"
(229mm)
*Drawing not to scale
OIL FURNA
CE FL
UE
WOOD, WOOD/OIL FLUE
(457mm)
(457mm)
14"
(356mm)
MINIMUM 52”
(1321mm)
24"
(610mm)
CLEAR
ANCE T
O
COMBUSTIBLES
CLEARANCE TO COMBUSTIBLES
18”
24”
1.25”
(32mm)
CLEAR
ANCE T
O
COMBUSTIBLES
SER
VICE CLEAR
ANCE
LEFT HAND RA CONFIGURATION (SIDE VIEW BLOWER MODULE)
9”
*Drawing not to scale
OIL FURNA
CE FL
UE
WOOD, WOOD/OIL FLUE
(457mm)
(229mm)
(610mm)
48” (1219mm)
ventIng cleaRance tO cOMBustIBles anD seRvIce cleaRances
CLEARANCE TO COMBUSTIBLES
24"
CLEAR
ANCE T
O
COMBUSTIBLES
SER
VICE CLEAR
ANCE
RIGHT HAND RA CONFIGURATION (SIDE VIEW BLOWER MODULE)
*Drawing not to scale
CLEAR
ANCE T
O
COMBUSTIBLES
OIL FURNA
CE FL
UE
WOOD, WOOD/OIL FLUE
18"
(457mm)
9"
(229mm)
(610mm)
1.25"
(32mm)
48"
(1219mm)
CLEAR
ANCE T
O
COMBUSTIBLES
SER
VICE CLEAR
ANCE
CLEAR
ANCE T
O
COMBUSTIBLES
SER
VICE CLEAR
ANCE
RIGHT HAND RA CONFIGURATION (REAR VIEW)
*Drawing not to scale
WOOD, WOOD/OIL FLUE
OIL FURNA
CE FL
UE
MAX 16" (406mm)
18" (457mm)
9"
(229mm)
14"
(356mm)
14"
(356mm)
MINIMUM 52"
(1321mm)
MINIMUM 40"
(1016mm)
24"
(610mm)
24"
(610mm)
NoTE
: incline of oil exhaust allows access to fresh
air inlet.
NoTE
Connection of solid fuel and oil fired appliances to a common chimney, see Section 5.1.4 of CSA B139-
09 and Section 5.2.7 of Can/CSa b365-01 for conditions allowing a single chimney for wood and oil.
Common chimney must be approved for use with woodburning appliances (2100°f) (1149°C).
h3.55
STRICTLy AdhERE To ALL IdENTIFIEd INSTALLATIoN CLEARANCES.
h3.56
vENTINg FRoM oIL FLUE ALWAyS INCLINES To ThE SAME SIdE oF ThE FURNACE ThAT ThE
BlOWeR MODule Is MOunteD On.