W415-1710 / B / 08.17.18
23
minimum venting requirements - propane
3.5 LVX38 venting configurations
(PROPANE ONLY)
0’
0’
Base of
air collar
10’
10’
15’
15’
20’
25’
20’
30’
40’
5’
3 1/4’
(40”)
1 1/2’
(18”)
2 1/2’
(30”)
38 1/2’
(462”)
5’
1 elbow zone
1-2 elbow zone
1-3 elbow zone
1-4 elbow zone
H
V
V+H ≤ 40 ft. H ≤ 10 ft.
(For longer vent runs, a power vent is
required).
V + H are measured from the centre of vent
elbows. Elbows are considered as 90º.
Two 45º elbows = One 90º elbow.
For 0 elbow configurations, V is a minimum
of 6’ to a maximum of 40’.
6’
(72”)
4 3/4’
(57”)
Vertical termination only.
No horizontal termination allowed.
Refer to appliance
specific GPV/PVA
instructions for other
venting configurations.