background image

NOTE: This manual does not include Remote Controller Operations, see the 
<<Remote Controller Instruction>> packed with the unit for details. 

Operating temperature

7

7

8

8

OPERATING INSTRUCTIONS

Airflow direction control

   Adjust the air flow direction properly, otherwise it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal louver using the remote 
   controller.
   Adjust the vertical louver manually.

  

To set the vertical air flow(Up--Down) direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow 
   direction. The horizontal louver can be moved at 

O

   a range of 6  for each press, or swing up and down
    automatically. Please refer to the   REMOTE 
    CONTROLLER OPERATION MANUAL    for details. 
   

   

   

To set the horizontal air flow direction (left - right)

Move the vertical louver manually to adjust the air flow 
in the direction you prefer.

IMPORTANT

: Before adjusting the vertical louvers, the 

supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
  REMOTE CONTROLLER OPERATION MANUAL    
for details. 

    

Do not operate the air conditioner for long periods with 
the air flow direction set downward in cooling or 
dehumidifying mode. Otherwise, condensation may 
occur on the surface of the horizontal louver causing
 moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is 
necessary. Always use the remote controller. 
When the air conditioner is started immediately after it 
was stopped, the horizontal louver might not move for 
approximately 10 seconds.
Open angle of the horizontal louver should not be set 
too small, as COOLING or HEATING performance may 
be impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed 
position.
When the air conditioner is connected to power (initial 
power), the horizontal louver may generate a sound for 
10 seconds, this is a normal operation.

CAUTION

,,

,,

,,

,,

OPERATING INSTRUCTIONS

Front panel

AUTO/COOL

Range

Range

Vertical 
louver

Manual operation

Mode

Temperature
Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures.If air 
    conditioner is used outside of the above conditions, certain safety protection features 
    might come into operation and cause the unit  to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 
    80%)

 , condensed water may drip out of the unit. Please sets the vertical air flow louver to

    its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: 

 For the unit adopts an Electric Heater, when the outside ambient  temperature

O

O

 is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to 
guarantee it running smoothly.

NOTE:

Cooling operation

Heating operation Drying operation

-15      50      5      122 

  For the models with low 

   temperature cooling system

0      50

32      122

-15      30

5        86

0      50

32      122

Open and lift the front panel up to an angle 
until it remains fixed  with a clicking sound. 

One press of the manual control switch will 
lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original 
position.

This switch is used for testing purposes 
only. You had better not choose it.
To restore the remote controller operation, 
use the remote controller directly.

CAUTION:

1

3

2

NOTE:

 The unit must be turned off before

operating the manual control button. If the 
unit is operational, continue pressing the 
manual control button until the unit is off.

O

O

17 C~32 C

O

O

(62 F~90 F)

O

O

0 C~30 C

O

O

(32 F~86 F)

O

O

10 C~32 C

O

O

(50 F~90 F)

Units are equipped with a switch to run emergency operation mode. It can be accessed by 
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.

Manual switch

Summary of Contents for NH19-24F

Page 1: ...esign and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Thank you very much for purchasing our air conditi...

Page 2: ...nditioner in the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabil...

Page 3: ...ll the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open...

Page 4: ...l receptor Signal receptor TIMER indicator This indicator illuminates when TIMER program is set ON OFF AUTO indicator This indicator illuminates when the air conditioner is in AUTO operation OPERATION...

Page 5: ...power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION OPERATING INSTRUCTIONS Front panel AUTO COOL Range Range Vertical louver Manual operati...

Page 6: ...air conditioner may be reduced and the air conditioner may stop running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal l...

Page 7: ...ng three situations and the set temperature has not been reached A When heating has just started B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrosting Cooling a...

Page 8: ...unit with power and then re connect the unit with power again Push the ON OFF button on the remote controller to restart operation 12 The protection of outdoor low temperature on some models The prot...

Page 9: ...s are excluded NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Any damages to the appliance due to water...

Page 10: ...ls utiles sur la mani re d utiliser et d entretenir correctement votre climatiseur Quelques petites mesures pr ventives vous permettront d pargner beaucoup de temps et d argent pendant la dur e de vie...

Page 11: ...ation 12 CONSEILS DE DEPANNAGE Conseils de d pannage 14 ATTENTION Faites appel un technicien agr pour la r paration ou l entretien de l appareil Faites appel un technicien agr pour l installation de l...

Page 12: ...mes de collecte o les d chets lectroniques peuvent tre mis au rebut au moins gratuitement par l utilisateur B Lorsque vous achetez un produit neuf le distributeur va reprendre l ancien produit au moi...

Page 13: ...er un choc lectrique ou un incendie cause de la chaleur g n r e Cela pourrait provoquer un choc lectrique Cela pourrait porter atteinte votre sant Assurez vous toujours d une mise la terre appropri e...

Page 14: ...rieur des sorties d air Coupez l alimentation principale quand l appareil n est pas utilis pendant longtemps Le fonctionnement avec les fen tres ouvertes peut provoquer l entr e d eau l int rieur de l...

Page 15: ...2 Entr e d air 3 Filtre air sous le panneau 4 Sortie d air 5 D flecteur horizontal 6 D flecteur vertical int rieur 7 Panneau d affichage 8 Tuyau de connexion tuyau de drainage Unit ext rieure 9 C ble...

Page 16: ...les mod les avec ioniseur AFFICHEUR DIGITAL Affiche la temp rature de consigne et le code d erreur de protection lorsque le climatiseur est en marche T moin de fr quence Ce t moin est compos de cinq...

Page 17: ...dans cette plage de temp ratures de fonctionnement Suggestion Pour l unit utilisant un radiateur lectrique lorsque la temp rature ext rieure ambiante est en dessous de 0 nous vous recommandons vivemen...

Page 18: ...l par la t l commande R f rez vous au MANUEL D UTILISATEUR DE LA TELECOMMANDE pour les d tails ATTENTION En mode de refroidissement ou de d shumidification n utilisez pas le climatiseur pendant longte...

Page 19: ...omatiquement contr l e sous le mode de d shumidification En mode de d shumidification si la temp rature ambiante est inf rieure 10 le compresseur cesse de fonctionner et il ne red marre que lorsque la...

Page 20: ...ence de solvant de poudre polir ou de solvants similaires Ils pourraient endommager ou d former la surface en plastique N utilisez jamais de l eau une temp rature sup rieure 40 pour nettoyer le pannea...

Page 21: ...ps suivez la proc dure suivante 1 Faites fonctionner le ventilateur pendant environ une demi journ e pour s cher l int rieur de l unit 2 Arr tez le climatiseur et d branchez l alimentation lectrique E...

Page 22: ...blanche peut tre provoqu e par l humidit g n r e par le d givrage quand le climatiseur red marre en mode CHAUFFAGE apr s le d givrage 3 Faible niveau sonore du climatiseur Il est possible qu un bruit...

Page 23: ...rature ext rieure Si le climatiseur ne parvient pas atteindre une chaleur confortable nous sugg rons d utiliser un syst me de chauffage suppl mentaire 9 Fonction de red marrage auto En cas de coupure...

Page 24: ...la t l commande peuvent tre puis es Remplacez les piles L heure programm e sur la minuterie est incorrecte Attendez ou annulez la programmation de la minuterie L unit ne refroidit pas ou ne chauffe pa...

Page 25: ...cernant la vente de ce produit Tout dommage caus l appareil par l eau les dommages caus s par les intemp ries de longues p riodes d humidit la condensation des produits chimiques ou produits d entreti...

Page 26: ...Support from Napoleon We re here to Help Services de Napol on Nous sommes l pour vous Phone T l phone 1 800 461 5581 Email Courriel care napoleonproducts com...

Page 27: ...ption et les sp cifications peuvent faire l objet de modifications sans pr avis dans un souci d am lioration des performances du produit Merci de contacter le revendeur local ou le fabricant pour les...

Reviews: