W415-1472 / 04.21.15
12
EN
2.5 RATING PLATE INFORMATION
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
SAMPLE
- INSTALL AND USE ONLY IN ACCORDANCE WITH
THE MANUFACTURER’S INSTRUCTIONS AND
LOCAL BUILDING CODES. MINIMUM CEILING
HEIGHT: 7FT (2.13M) HEARTH EXTENSION /
COMBUSTIBLE FLOOR PROTECTION: IF
INSTALLED ON A COMBUSTIBLE FLOOR, UNIT
MUST BE PLACED ON A NON-COMBUSTIBLE
FLOOR PROTECTOR EXTENDING 6” IN FRONT.
- DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
- REPLACE GLASS WITH ONLY CERAMIC GLASS.
DANGER: RISK OF ELECTRICAL SHOCK.
DISCONNECT POWER BEFORE SERVICING
UNIT.
- KEEP VIEWING DOOR TIGHTLY CLOSED
DURING OPERATION.
- CONTACT LOCAL BUILDING AND FIRE
OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR LOCAL
AREA.
- SUITABLE FOR USE IN MOBILE HOMES WHEN
USED WITH OUTSIDE AIR INSTALLATION KIT.
- REFER TO INSTALLATION INSTRUCTIONS OR
LOCAL BUILDING CODES WHEN PASSING
EXHAUST SYSTEM THROUGH COMBUSTIBLE
WALL OR CEILING.
LISTED PELLET FUEL BURNING ROOM HEATER
TESTED TO: ASTM E 1509, UL1482, ULC S628
MODEL NPI45
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
U.S. ENVIROMENTAL PROTECTION AGENCY Certified to comply with July 1992 Particulate Emission Standards
WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
NPI45
MINIMUM CLEARANCES TO COMBUSTIBLE
Sidewall
A
8”
Mantel
B
8”
Floor Protector
C
6”
Recess Width
D
31 1/2”
Recess Height
E
26 1/2”
Recess Depth
F
16”
Mantel Depth
G
10”
INPUT RATING
MIN
1
LB/HR
MAX
5
LB/HR
ELECTRICAL RATING
120V 3.6A 60HZ
MASONRY FIREPLACE INSTALLATION
BUILT-IN FIREPLACE INSTALLATION
(FRONT VIEW)
BUILT-IN FIREPLACE INSTALLATION
(SIDE VIEW)
WOOD MANTEL
ENCLOSURE
INSERT
B
D
E
MANTEL
ENCLOSURE
BASE DE
PROTECTION
MANTEL
INSERT
B
A
HEARTH EXTENSION
C
E
C
B
G
F
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
REFERENCE #
W/N 16064
This wood appliance needs periodic inspection and repair for proper operation.
Consult the owner’s manual for further information. it is against federal
regulations to operate this wood appliance in a manner inconsistent with the
operating instructions in the owner’s manual. / Cet appareil au bois doit faire
l'objet d'une inspection et d'un entretien périodiques pour un fonctionnement
adéquat. Consultez le manuel d'instructions pour plus d'information. Les
règlements fédéraux interdisent d'utiliser cet appareil de chauffage d'une
manière allant à l'encontre des instructions de fonctionnement contenues dans
ce manuel.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with
2015 particulate emissions standards. Not approved for sale after May 15,2020.
Certifié conforme à la norme d’ émanation de particles de 2015. Non approuvé
pour la vente après le 15 mai, 2020. 40 CFR Part 60, Subpart AAA. 2.4 Grams
Per Hour / 2015 Crib Wood / 2.4 Grammes par heure / Crib Wood 2015.
W385-2047 / A
MODEL / MODÈLE: NPI45
Summary of Contents for NPI45
Page 48: ...W415 1472 04 21 15 48 EN 67 20 29 58 41 38 43 44 63 57 60 6 11 3 NPI45 REPLACEMENT PARTS...
Page 54: ...W415 1472 04 21 15 54 EN 14 0 SERVICE HISTORY 43 1...
Page 55: ...W415 1472 04 21 15 55 EN 15 0 NOTES 44 1...
Page 106: ...106 W415 1472 04 22 15 FR 67 20 29 58 41 38 43 44 63 57 60 6 11 3 PI CES DE RECHANGE DU NPI45...
Page 114: ...114 W415 1472 04 22 15 FR 15 0 NOTES 44 1...
Page 115: ...115 W415 1472 04 22 15 FR 44 1...