Floor Protection

Minimum Clearance to Combustibles

Alcove Installation

Appliance Placement

BACK WALL

B

SIDE WALL

A

BACK WALL

C

SIDE WALL

F

D

E

E

PARALLEL & CORNER

SINGLE WALL CONNECTOR

DOUBLE WALL CONNECTOR

Sidewall (A)

19” (48.3cm)

Sidewall to fl ue (B)

28 7/8” (73.3cm)

Backwall (C)

17 1/2” (44.5cm)

12 1/2” (31.8cm)

Backwall to fl ue (D)

21” (53.3cm)

16” (40.6cm)

Corner (E)

11" (27.9cm)

7" (17.8cm)

Ceiling (F)

84" (213.4cm)

75” (190.5cm)

Clearances can be reduced with shielding acceptable to local authorities. Re-
duced installation must comply with NFPA 211 or CAN/CSA-B365.

!

WARNING

• 

Do not install into any area having less than 7 feet (2.1m) 
(ceiling to appliance bottom, excluding hearth height).

19"

(48.3cm)

28 

7

/

8

"

(733.4mm)

ALCOVE

48” (122cm)

MAX

A

B

F

G

K

J

J

I

L

M

M

N

MINIMUM FLOOR PROTECTION

FRONT (L)

SIDES (M)

BACK (N)

CANADA

18" (45.7cm)

8" (203mm)

USA

16" (40.6cm)

If a section of horizontal chimney connector is used, fl oor 
protection is required under the chimney connector and 2” 
(51mm) beyond each side.

note:

Product information provided is not complete and is subject to change 
without notice. Please consult the installation manual for the most up to 
date installation information.

We recommend having your Napoleon wood burning appliance 
installed by a qualifi ed technician. However, should you choose 
to install the appliance yourself, it is extremely important that you 
follow all installation instructions for the appliance, the chimney and 
connector if applicable, as well as local building codes. At the very 
least, draw a detailed plan of your installation, including clearance 
dimensions to combustibles, and have your authorized dealer 
review them to confi rm that they conform to the relative installation 
parameters.

When positioning the appliance, it may be necessary to adjust 
its position to prevent the chimney/vent system from intersecting 
with a framing member and to meet the minimum combustible 
clearance requirements. Its location should also avoid the potential 
for drapes or doors to swing within 48” (122cm) in front of the 
appliance to prevent a fi re hazard.

note:

K

J

H

I

ALCOVE

PARALLEL & 

CORNER

SINGLE WALL 

CONNECTOR

DOUBLE WALL 

CONNECTOR

Ceiling (G)

N/A

75" (190.5cm)

Sidewall (H)

19” (48.3cm)

Sidewall to fl ue (I)

28 7/8” (73.3cm)

Backwall (J)

12 1/2” (31.8cm)

Backwall to fl ue (K)

16” (40.6cm)

Reviews: