5
W415-0434 / G / 08.08.11
2.1 DIMENSIONS
2.2 GENERAL
INSTRUCTIONS
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER
to
conform with local codes. Installation practices vary from region to region and it is important to know the
speci
fi
cs that apply to your area, for example in Massachusetts State:
•
This product must be installed by a licensed plumber or gas
fi
tter when installed within the commonwealth
of Massachusetts.
•
The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.
•
The appliance off valve must be a “T” handle gas cock.
• The
fl
exible connector must not be longer than 36 inches.
•
A Carbon Monoxide detector is required in all rooms containing gas
fi
red appliances.
•
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE
FRONT FACE OF THE UNIT.
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
!
WARNING
!
WARNING
THE DOOR FOR THIS APPLIANCE IS SOLD SEPARATELY. THE DOOR MUST BE INSTALLED AND
CLOSED BEFORE OPERATION BEGINS. SEE “DOOR INSTALLATION” SECTION FOR FURTHER
DETAILS.
41
1
/
2
"
36"
11"
24"
18"
37
1
/
4
"
18
5
/
8
"
16"
4" DIA.
7" DIA.
7"
GAS
INLET
ELECTRICAL INLET
LEFT SIDE