background image

W415-2350 / 10.28.19

EN

34

  

replacement parts

10.0  replacement parts

!

WARNING

• 

Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved 
with this appliance may result in property damage or personal injury.

Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can 
be ordered through your Authorized dealer / distributor. 

For warranty replacement parts, a photocopy of the original invoice will be required to honour the 
claim.

When ordering replacement parts always give the following information:
• 

Model & Serial Number of appliance

• 

Installation date of appliance

• Part 

number

• 

Description of part

• Finish

Parts, part numbers, and availability are subject to change without notice.

Parts identifi ed as stocked will be delivered within 2 to 5 business days for most delivery 
destinations.

Parts not identifi ed as stocked will be delivered within a 2 to 4 week period, for most cases.

Parts identifi ed as ‘SO’ are special order and can take up to 90 days for delivery.

Summary of Contents for TORCH GT8N

Page 1: ...Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas...

Page 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Page 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sootin...

Page 4: ...mobile home 16 4 0 framing 17 4 1 minimum clearance to combustibles 18 4 2 minimum enclosure clearances 19 4 3 nailing tab installation 20 4 4 stand off assembly 20 5 0 finishing 21 5 1 mounting cabi...

Page 5: ...permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for...

Page 6: ...d with a power cord it must be connected into a properly grounded receptacle The grounding prong must not be removed from the cord plug The following does not apply to inserts as long as the required...

Page 7: ...ressure not to exceed 13 Manifold Pressure 10 w c P Minimum Supply Pressure 11 w c P Maximum Supply Pressure 13 w c P Pression au Collecteur 10 d une colonne d eau P Pression d Alimentation Min 11 d u...

Page 8: ...op inside of the rebox Use only Wolf Steel venting components Minimum and maximum vent lengths for both horizontal and vertical installations and air terminal locations for either system are set out i...

Page 9: ...k or balcony N 16 406 4mm 16 406 4mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without open...

Page 10: ...iance if 7 2m maximum horizontal run is required 18 457mm 7 2m 0 1 2 3 4 5 6 7 8 9 10 10 9 8 7 6 5 4 3 2 1 1 5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT REQUIRED VERTICAL RISE IN FEET VT See graph to...

Page 11: ...d 1 4 6 3mm N A Rise per foot allowable 0 N A Vertical run when not venting horizontally 24 610mm 19 1 2 6m Horizontal run 4 102mm 5 1 5m 0 1 2 3 4 5 6 7 8 9 10 20 HORIZONTAL VENT RUN PLUS OFFSET IN F...

Page 12: ...aterials away from vent pipe may cause re For gas stoves only If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood ooring the appliance shall be...

Page 13: ...0002 not supplied between the pipe and the restop assembly C In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materials such as in...

Page 14: ...ied C Insert the vent pipes through thee restop maintaining the required clearances to combustibles Holding the sir terminal lettering in an upright readable position secure to the exterior wall and m...

Page 15: ...roof Do not nail through the lower portion of the ashing Make weather tight by sealing with caulking Where possible cover the sides and top edges of the ashing with roo ng material F Aligning the sea...

Page 16: ...d be installed to provide suf cient movement for shifting the burner assembly on its side to aid with servicing components Check for gas leaks by brushing on a soap and water solution Do not use open...

Page 17: ...ain air space clearance may cause over heating and re Prevent contact with sagging or loose insulation or framing and other combustible materials Block opening into the chase to prevent entry of blown...

Page 18: ...led in this space ie baseboards must leave 2 51mm of unobstructed clearance to allow for full rotation of the control door COMBUSTIBLE NON COMBUSTIBLE 1 25mm 1 25mm 0 IF NON COMBUSTIBLE FINISHING IS U...

Page 19: ...M TORCH TM FRAMING OPENING DIMENSIONS INSTALLATION FINISHING OPENING DIMENSIONS 1 2 3 44 1 4 1124mm 34 7 8 886mm 14 1 2 368mm 7 178mm 11 5 8 295mm INSIDE CHASE OUTSIDE CHASE INTERIOR BUILT OUT EXTERIO...

Page 20: ...19 EN 20 framing Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self tapping screws included in the manual baggie 4 3 nailing tab installation 1 2 4 4 st...

Page 21: ...mension as illustrated Do not strike slam or scratch Do not operate appliance with glass removed cracked or scratched Facing and or nishing material must never overhang into the appliance opening The...

Page 22: ...x remaining mounting holes Align the keyholes of the frame to the heads of the fasteners and slide the frame down onto the fasteners Ensure the frame is plumb and level before tightening the fasteners...

Page 23: ...ard and remove from the appliance SAFETY SCREEN SAFETY SCREEN SAFETY SCREEN WARNING Glass may be hot Do not touch glass until cooled If equipped with door latches that are part of a safety system they...

Page 24: ...oor Reverse these steps to re install the screen and door Ensure safety screen is installed correctly OPEN CLOSED 5 3 door removal WARNING Glass may be hot Do not touch glass until cooled If equipped...

Page 25: ...perfectly square and the control door will close without rubbing against the sides of the frame tighten all screws H Open the control door I Insert the door stop chain into the receiving slot in the c...

Page 26: ...ng problems Do not place any media glass or vermiculite in or around the pilot opening and or on the burner ports This will interfere with the pilot operation Evenly spread the glass media onto the me...

Page 27: ...appropriate ags on the wire harness The wire harness is labeled TR top right BR bottom right TL Top left and BL bottom left F Secure the wires into the clips at both sides and the bottom of the frame...

Page 28: ...NATIONAL ELECTRICAL CODE in the United States 1 2 3 4 YELLOW BROWN W H I T E B L A C K IGNITOR WIRE IGNITOR GAS VALVE SWITCH CONTROL MODULE 110v POWER SUPPLY GFI Ground Fault Interrupter G R O U N D I...

Page 29: ...itch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to lowest setting if equipped B Turn off...

Page 30: ...ment AIR SHUTTER OPENINGS P 5 16 7 9mm DIA x2 NG 3 16 4 7mm DIA x1 It is important to periodically perform a visual check of the burner ame Compare them to the illustration provided 8 2 venturi adjust...

Page 31: ...r 5 If your appliance is equipped with a safety barrier cleaning may be necessary due to excessive lint dust from carpeting pets etc simply vacuum using the brush attachment 6 If your appliance is equ...

Page 32: ...quali ed service technician The rebox becomes very hot during operation Let the appliance cool completely or wear heat resistant gloves before conducting service Never vacuum hot embers Do not paint t...

Page 33: ...broken glass or damaged components Be sure to vacuum up any broken glass from inside the appliance before operation GLASS RETAINERS GASKET GLASS TOP 9 3 door glass replacement WARNING Do not use subst...

Page 34: ...warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of applian...

Page 35: ...celain panel 2 1 Stocked Stocked Yes W385 2010 Napoleon logo 9 10 11 8 W562 0009 Door gasket Yes Safety barrier 4 3 1 2 6 5 For replace parts refer to valve train assembly section 8 9 12 13 10 11 7 Gl...

Page 36: ...ked Stocked Yes Yes W100 0104 Burner assembly 22 23 24 21 Shut off valve W725 0059 Yes Ignition cable W750 0184 Yes Burner ori ce 56 NG W455 0085 Yes 25 Valve NG W725 0052 Yes W725 0053 Valve P Wire h...

Page 37: ...rated Stocked Stocked W010 3496 Control panel assembly TFK SS8 7 4 6 Screen retainer X2 TFK SS8 W500 0800 W010 1686 LED light X4 TFK SS8 LK8 5 1 3 2 3 5 4 6 7 TFK8 TFSS8 3 2 1 LK8 W707 0019 Transforme...

Page 38: ...or other obstructions Flame is impinging on the combustion chamber Open air shutter to increase the primary air Check the input rate check the manifold pressure and ori ce size as speci ed by the rati...

Page 39: ...is cracked or broken Spark gap is incorrect Spark gap should be 0 125 3 2mm from the electrode tip to the sensor tip Remote wall switch is in OFF position burner comes on Wall switch is mounted upsid...

Page 40: ...not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather...

Page 41: ...EN W415 2350 10 28 19 41 troubleshooting 14 0 notes...

Page 42: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne...

Page 43: ...r un installateur quali une agence d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appa...

Page 44: ...ux br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajust...

Page 45: ...ut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement De m me installe...

Page 46: ...s une maison mobile 59 4 0 ossature 60 4 1 d gagements minimaux aux mat riaux combustibles 61 4 2 d gagements minimaux de l enceinte 62 4 3 installation des supports de xation 63 4 4 assemblage des es...

Page 47: ...s les endroits o les codes locaux ne l interdisent pas Cet appareil ne doit fonctionner qu avec le gaz sp ci sur la plaque d homologation Cet appareil ne peut tre converti un autre type de gaz moins d...

Page 48: ...o le souf erie est quip d un cordon d alimentation il doit tre connect une r ceptacle correctement mise la terre La che de mise la terre ne doit pas tre retir du cordon d alimentation Ce qui suit ne...

Page 49: ...AVERTISSEMENT N ajoutez pas cet appareil aucun mat riau devant entretien contact avec les ammes autre que celui qui est fourni avec cet appareil par le fabricant Maximum horizontal extension X See ins...

Page 50: ...s ensembles d vents permettent une vacuation horizontale prolong e de l appareil Lorsque vous utilisez les composants d vacuation Wolf Steel certi s utilisez uniquement les ensembles de terminaison su...

Page 51: ...doivent pas tre combin s Les composants d vacuation de fournisseurs diff rents ne doivent pas tre combin s Les terminaisons ne doivent pas tre ench ss es dans un mur ou un parement Ces ensembles d ve...

Page 52: ...u dessus du toit O 2 0 6m 2 0 6m D gagement des murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les...

Page 53: ...e de 7 pi 2 1m est requise 18 457mm 7 2 1m 0 1 2 3 4 5 6 7 8 9 10 10 1 5 LONGUEUR DES COURSES HORIZONTALES PLUS LES D VIATIONS EN PIEDS HT COURSE VERTICALE REQUISE EN PIEDS VT Consultez le graphique p...

Page 54: ...S O l vation par pied acceptable 0 0mm S O Course verticale sans course horizontale 24 610mm 19 1 2 2 9m Course horizontale 4 102mm 5 1 5m 0 1 2 3 4 5 6 7 8 9 10 20 LONGUEUR DES COURSES HORIZONTALES...

Page 55: ...tout autre mat riau l cart du conduit d vent un risque d incendie pourrait s ensuivre Pour les po les gaz seulement Si l appareil est install directement sur un tapis sur une surface de vinyle ou tou...

Page 56: ...pliquez une scellant silicone rouge W573 0002 non fourni entre le conduit d vacuation et l espaceur coupe feu Calfeutrage Protecteur du conduit d vacuation Protecteur du conduit d vacuation Collet de...

Page 57: ...es gaines dans le coupe feu tout en conservant le d gagement n cessaire aux mat riaux combustibles En soutenant la terminaison les inscriptions tant l endroit et lisibles xez la au mur ext rieur et re...

Page 58: ...eure du solin Imperm abilisez le en le scellant avec du calfeutrage Si possible recouvrez les c t s et le bord sup rieur du solin avec des mat riaux de couverture F Alignez les joints de la terminaiso...

Page 59: ...ue vous manipulez des conduites de gaz soutenez la soupape de gaz pour viter que les conduites ne se plient Le raccord exible de l alimentation en gaz devrait tre suf samment mobile pour permettre de...

Page 60: ...isolant qui s affaisse avec l ossature ou avec tout autre mat riau combustible Bloquez l entr e de l enceinte pour emp cher l in ltration d isolant souf Assurez vous que l isolation et les autres mat...

Page 61: ...fourni SECTIONS D VENTS VERTICALES Un d gagement minimal aux mat riaux combustibles de 1 25mm est requis sur toutes les courses verticales Utilisez l espaceur coupe feu W500 0358 non fourni SANS LE C...

Page 62: ...TORCH TM TORCH TM INSTALLATION 1 2 3 441 4 1124mm 141 2 368mm 7 178mm 347 8 886mm 115 8 295mm DIMENSIONS DE L OUVERTURE DE FINITION DIMENSIONS DE L OUVERTURE CHARPENT E 4 2 d gagements minimaux de l...

Page 63: ...xez les quatre supports de xation fournis sur les c t s du caisson ext rieur tel qu illustr l aide des huit vis auto perceuses incluses dans le sac de votre manuel 4 3 installation des supports de xat...

Page 64: ...pour votre appareil voir les illustrations suivre Ne frappez pas ne claquez pas et n gratignez pas la porte vitr e Ne faites pas fonctionner l appareil lorsque la porte vitr e est enlev e ssur e bris...

Page 65: ...support du cabinet avec les t tes des attaches et faites glisser le support vers le bas sur les attaches Assurez vous que le support du cabinet est d aplomb et de niveau avant de serrer les attaches...

Page 66: ...rri re de protection AVERTISSEMENT La vitre peut tre chaude Ne touchez pas la vitre jusqu ce qu elle ait refroidi Si quip avec les loquets de porte qui font partie d un dispositif de s curit ils doive...

Page 67: ...ion et la porte Assurez la ecran de protection est correctement install OUVERT FERM 5 3 enl vement de la porte AVERTISSEMENT La vitre peut tre chaude Ne touchez pas la vitre jusqu ce qu elle ait refro...

Page 68: ...ne fois que le contour est parfaitement d querre et que l assemblage de la porte de contr le peut fermer sans frotter les c t s du contour serrez toutes les vis H Ouvrez la porte de contr le I Ins rez...

Page 69: ...t cr er de la suie Ne placez aucun braises vitri es ni vermiculite sur ou autour de l ouverture de la veilleuse ni sur les ori ces du br leur Ceci interf rait avec l op ration de la pilote parpillez s...

Page 70: ...TR pour le coin sup rieur droit BR pour le coin inf rieur droit TL pour le coin sup rieur gauche et BL pour le coin inf rieur gauche F Fixez les ls dans les attaches de chaque c t et dans le bas du co...

Page 71: ...LECTRICAL CODE ANSI NFPA 70 1996 aux tats Unis 1 2 3 4 1 1 2 5 INTERRUPTEUR ALIMEN TATION 110v Bo te de d rivation avec 2 r ceptacles 7 5 5 Illustration uniquement pour r f rence Suivre les instructio...

Page 72: ...uctions de couper l alimentation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R gler le thermostat la r glage le plus bas si quip B Tournez l interrupteur murale de l app...

Page 73: ...RE DU VOLET D AIR P 5 16 7 9mm DIA x2 GN 3 16 4 7mm DIA x1 Il est important d effectuer p riodiquement une inspection visuelle de la amme du br leur Comparez les ces illustrations RACCORD CANNEL NPT 1...

Page 74: ...br leur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du brosse...

Page 75: ...amme l aide d une morceau de laine d acier ou un tampon r curage Scotch BriteMD a n de retirer toute trace d oxydation Nettoyez l assemblage du pilote l aide d un aspirateur muni d une brosse souple I...

Page 76: ...vous enlevez et jetez des d bris de verre ou des composants endommag s Assurez vous d aspirer tous les d bris de verre l int rieur de l appareil avant de le faire fonctionner PATTES DE RETENUE JOINT D...

Page 77: ...ement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et nu...

Page 78: ...i W385 2010 Logo Napol on 9 10 11 8 W562 0022 Joint d tanch it de la porte Oui Barri re de protection 4 3 1 2 6 5 Pour les pi ces de rechange voir assemblage de la soupape 8 9 12 13 10 11 7 Braises vi...

Page 79: ...Assemblage du br leur 22 23 24 21 Coupez soupape W725 0059 Oui C ble d allumage W750 0184 Oui Injecteur de veilleuse 56 GN W455 0085 Oui 25 Soupape GN W725 0052 Oui W725 0053 Soupape P Harnais de ls...

Page 80: ...le TFK SS8 7 4 6 W500 0800 W010 1686 Lumi re DEL X4 TFK SS8 et LK8 5 1 3 2 3 5 4 6 7 TFK8 TFSS8 3 2 1 LK8 W707 0006 Transformateur LK8 W750 0187 Harnais de ls LK8 W475 0604 C t du cabinet X2 TMCK SS...

Page 81: ...au savonneuse Du carbone se d pose sur la vitre les b ches ou les parois de la chambre de combustion Le volet d air est bloqu Assurez vous que l ouverture du volet d air n est pas bloqu e par des bres...

Page 82: ...r et au module de contr le V ri ez si l tincelle ne saute pas vers le couvercle de l allumeur Remplacez le l si son isolant est bris ou ef loch Remplacez l lectrode si l isolateur de c ramique est f l...

Page 83: ...s p riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de Napol on Durant les dix premi res ann es Napol on remplacera ou r parera...

Page 84: ...US S D DE E 4 40 0 A AN NS S D D E EXISTENCE C C C C C CO O O O O ON N N N N N N N NS S S S S SA A A A A AC C C CR R R R R S S L L LA A C CO ON NC CE EP PT TIO ON N D DE PR RODUITS DE CONFORT 7200 Rou...

Reviews: