12
W415-0847 / A / 06.08.10
MINIMUM CLEARANCES TO COMBUSTIBLES:
-
18” to top
-
1” to sides
-
8” to bottom
-
0” to rear (cabinet)
-
1/2” to rear (appliance)
THIS APPLIANCE MUST BE INSTALLED IN THE CABINET PROVIDED. THE CABINET IS DESIGNED
TO BE INSTALLED ON FINISHED SURFACES.
THIS APPLIANCE CAN BE RECESSED INTO AN ALCOVE A MAXIMUM OF 12” PROVIDED THAT
ALL CLEARANCES ARE MAINTAINED.
THE CABINET MAY BE INSTALLED DIRECTLY ONTO A COMBUSTIBLE SURFACE.
4.1 CLEARANCE TO COMBUSTIBLES
!
WARNING
TYPICAL
INSTALLATION
(OUTSIDE WALL)
ALCOVE
INSTALLATION
(INSIDE WALL)
18” MIN.
8” MIN.
8’
12” MAX.
18”
MIN.
8”
MIN.
12” MAX.
1” MIN.
1” MIN.
4.0 FRAMING