7
W415-0847 / A / 06.08.10
2.3 GENERAL
INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION
AND QUALITY!
RATES AND EFFICIENCIES
NATURAL GAS
PROPANE
Altitude
0 - 2,000*
0 - 2,000*
Maximum input
6,000
6,000
Minimum Inlet Gas Supply Pressure
4.5” Water Column
11” Water Column
Maximum Inlet Gas Supply Pressure
7” Water Column
13” Water Column
Manifold Pressure Under Flow Conditions
3.5” Water Column
10” Water Column
* When the appliance is installed at elevations above 2,000ft and in the absence of speci
fi
c recommendations
from the local authority having jurisdiction, the certi
fi
ed altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. For rating plate location,
see either “INSTALLATION OVERVIEW” or “RATING PLATE INFORMATION” section. This appliance is not
convertible for use with other gases, unless a certi
fi
ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
The rating label is located under the control panel and is chained to the appliance.
DO NOT REMOVE.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
2.4 RATING PLATE INFORMATION
CERTIFIED UNDER : ANSI Z21.11.2a-2008 VOLUME II, UNVENTED ROOM HEATER
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME,
WHERE NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES.
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES ADEQUATE COMBUSTION AND VENTILATION AIR.
ALTITUDE
INPUT
ORIFICE
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
0-2000FT (0-1370m)
6,000 BTU/h
#69
0-2000FT (0-1370m)
6,000 BTU/h
#56
CERTIFIED FOR USA
GVFT8N
MODEL
GVFT8P
MODEL
W385-0480 / A
GVFT8
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAME. DO NOT USE ACCESSORIES
NOT APPROVED FOR USE WITH THIS APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” FLOOR
8”
SIDES 1”
BACK 0”
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
SERIAL NUMBER:
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
REFERENCE #16437
(NATURAL GAS)
(PROPANE)
CONTROL:
COPRECI T15
CONTROL:
COPRECI T15
OXY PROTECTOR SIT:
#9099
OXY PROTECTOR SIT:
#9266
SAMPLE
SAMPLE
SAMPLE
TLY LOCATED, MANUF
FOR USE WITH THE TYP
SE WITH OTHER GASE
E COMBUSTION A
DE
UT
RIFICE
LUM
COLUMN
COLUMN
MANIFOLD P
NIMUM SU
MAXIMUM SUP
0-200
6,
LE
LE
GVFT
EL
APPLIANCE, WHICH WILL C
OPER INSTALLATION
RY OR LOSS OF LIFE. REFER
MUST BE PERFORMED BY A
MATERIALS
0
ABOVE. FOR FINISHING
ANUAL.
G: 115v 0.82AMP, 60H
(PROPA
ECI T15
CONTROL:
C
99
OXY PR