7
W415-1606 / 09.09.16
2.3 GENERAL INFORMATION
* When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m).
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for
mobile home installation. The natural gas model can only be installed
in a mobile home that is permanently positioned on its site and fueled
with natural gas. This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home, where not prohibited
by local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a
certified kit is used.
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with the appliance and must be installed.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
70.78%
CWHD48
70.78%
WHD48
70.78%
WHD48
Cote énergétique des foyers à gaz
Basée sur la norme CSA P.4.1-02
Modèle No.
70.78%
CWHD48
Cote énergétique des foyers à gaz
Basée sur la norme CSA P.4.1-02
Modèle No.
FRENCH:
ENGLISH:
EN
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
RATES AND EFFICIENCIES
NG
P
Altitude (FT)
0-4,500*
0-4,500*
Max. Input (BTU/hr)
28,000
28,000
Min. Inlet Gas Supply
Pressure
4.5" (11mb) w.c.
11" (27mb) w.c.
Max. Inlet Gas Supply
Pressure
13" (32mb) w.c.
13" (32mb) w.c.
Manifold Pressure (Under
Flow Conditions)
3.5" (9mb) w.c.
10" (25mb) w.c.
TITLE:
RATING PLATE
WHD48
REVISION:
DWG#:
W385-2131
DATE:
06.22.16_
R.T.
MAX SIZE:
8.5" X 4.75"
HOLE TO BE 0.250"Ø
MATERIAL:
CLASS III A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER.
MIN. LETTERING FOR "
NOT FOR USE WITH SOLID FUEL.
", "
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI.
" TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM WHD48 015416
W385-2131
DIRECT VENT, VENTED GAS FIREPLACES. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE
INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT
ANSI Z223.1, OR CSA B149, INSTALLATION CODES.
FOR USE WITH BARRIER W565-0227.
FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE
MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE
APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES
SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. CODES. INSTALLER L’APPAREIL SELON LES
CODES OU RÈGLEMENTS LOCAUX, OU EN L’ABSENCE DE TELS RÈGLEMENTS, SELON LES
CODES D’INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
POUR UNE UTILISER AVEC
BARRIÈRE
W565-0227
. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE
MANUEL D'INSTALLATION.
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC) 4001659
(WUSA)
WHD48N
CWHD48N
MODEL
CWHD48P WHD48P
0-4500FT (0-1370m)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
28,000 BTU/h
INPUT / ALIMENTATION
28,000 BTU/h
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING
:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES *:
MANTEL / CEILING 15"
MANTEAU / PLAFOND
15"
SIDES 7"
CÔTÉS
7"
VENT SIDES / BOTTOM 1"
CÔTÉS DE L'ÉVENT / ÉVENT INFÉRIEUR
1"
FLOOR 6" PLANCHER
6"
VENT TOP 3" ÉVENT SUPÉRIEUR
3"
* SEE INSTALLATION MANUAL FOR FURTHER INFORMATION / VOIR MANUEL D'INSTALLATION POUR PLUS
D'INFORMATION.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURS D'ÉVACUATION MINIMALE
ET MAXIMALE.
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITRÉES HOMOLOGUÉES SEULEMENT AVEC CETTE UNITÉ.
AVERTISSEMENT:
N’AJOUTEZ PAS À CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM. /
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER AU
MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER
ET RESCELLER L'ÉVENT APRÉS AVOIR ASSURÉ LE MAINTIEN DU SYSTÉME DE PRISE D'AIR.
ELECTRICAL RATING: 115V, 60HZ. LESS THAN 12 AMPERES
SPÉCIFICATIONS ÉLECTRIQUES: 115V, 60HZ. MOINS DE 12 AMPÈRES
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
SERIAL NUMBER/NO. DE SÉRIE:
WHD48
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIÉ CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
REDUCED INPUT / ALIMENTATION RÉDUITE
P4
19,000 BTU/h
23,000 BTU/h
70.8%
70.8%
MANIFOLD PRESSURE:
3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR:
3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE:
4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN:
4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE:
7" W.C. (NG)
PRESSION D'ALIMENTATION MAX:
7" D'UNE
COLONNE D'EAU (GN)
MANIFOLD PRESSURE:
10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR:
10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE:
11" W.C. (LP)
PRESSION D'ALIMENTATION MIN:
11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE:
13" W.C. (LP)
PRESSION D'ALIMENTATION MAX:
13" D'UNE
COLONNE D'EAU (P)
WOLF STEEL LTD.
SAMPLE
2.4 RATING PLATE INFORMATION
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.