2.1 DIMENSIONS
This gas appliance should be installed and serviced by a qualifi ed installer to conform with local codes.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your
area, for example: in Massachusetts State:
•
The appliance off valve must be a “T” handle gas cock.
• The
fl exible connector must not be longer than 36” (914.4mm).
•
The appliance is not approved for installation in a bathroom unless the appliance is a direct vent sealed
combustion product.
•
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
• WARNING:
This product must be installed by a licensed plumber or gas fi tter when installed within the
commonwealth of Massachusetts.
•
Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00
through 7.00.
!
WARNING
* CARBON MONOXIDE POISONING MAY LEAD TO DEATH
EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE,
DIZZINESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE HEATER MAY NOT BE WORKING
PROPERLY. GET FRESH AIR AT ONCE! HAVE HEATER SERVICED.
SOME PEOPLE---PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE
UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--- ARE MORE AFFECTED BY
CARBON MONOXIDE THAN OTHERS.
FAILURE TO KEEP THE PRIMARY AIR OPENING(S) OF THE BURNER(S) CLEAN MAY RESULT IN
SOOTING AND PROPERTY DAMAGE.
THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES. THIS APPLIANCE IS
INTENDED FOR SUPPLEMENTAL HEATING.
OBJECTS PLACED IN FRONT OF THE HEATER SHOULD BE KEPT A MINIMUM OF 48” (1219.2mm)
AWAY FROM THE FRONT FACE OF THE APPLIANCE. KEEP APPLIANCE AREA CLEAR AND FREE
FROM COMBUSIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES AND REPLACEMENT PARTS (BLOWERS,
LOUVRES, TRIMS, GAS COMPONENTS, VENT COMPONENTS, ETC.) COULD RESULT IN A SAFETY
HAZARD AND WILL VOID THE LIMITED LIFETIME WARRANTY.
THIS APPLIANCE MUST NOT BE INSTALLED IN A BATHROOM.
DO NOT OPERATE WITHOUT CERAMIC CATALYST IN PLACE.
2.2 GENERAL
INSTRUCTIONS
W415-1158 / A / 11.19.13
5
EN
22"
559mm
19 1/4"
487mm
6 7/8"
175mm
23 3/4"
605mm
32 3/8"
822mm