background image

2.1 DIMENSIONS

This gas appliance should be installed and serviced by a qualifi ed installer  to conform with local codes.  
Installation practices vary from region to region and  it is important to know the specifi cs that apply to your 
area, for example: in Massachusetts State:
• 

The appliance off valve must be a “T” handle gas cock.

• The 

fl exible connector must not be longer than 36” (914.4mm).

• 

The appliance is not approved for installation in a bathroom unless the appliance is a direct vent sealed 
combustion product.

• 

A carbon monoxide detector is required in all rooms containing gas fi red appliances.

• WARNING: 

This product must be installed by a licensed plumber or gas fi tter when installed within the 

commonwealth of Massachusetts.

• 

Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00 
through 7.00.

!

WARNING

* CARBON MONOXIDE POISONING MAY LEAD TO DEATH

EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, 

DIZZINESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE HEATER MAY NOT BE WORKING 

PROPERLY. GET FRESH AIR AT ONCE! HAVE HEATER SERVICED. 

SOME PEOPLE---PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE 

UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--- ARE MORE AFFECTED BY 

CARBON MONOXIDE THAN OTHERS.

FAILURE TO KEEP THE PRIMARY AIR OPENING(S) OF THE BURNER(S) CLEAN MAY RESULT IN 

SOOTING AND PROPERTY DAMAGE.

THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. 

THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES. THIS APPLIANCE IS 

INTENDED FOR SUPPLEMENTAL HEATING.

OBJECTS PLACED IN FRONT OF THE HEATER SHOULD BE KEPT A MINIMUM OF 48” (1219.2mm) 

AWAY FROM THE FRONT FACE OF THE APPLIANCE. KEEP APPLIANCE AREA CLEAR AND FREE 

FROM COMBUSIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. 

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH 

THIS APPLIANCE. USING NON-LISTED ACCESSORIES AND REPLACEMENT PARTS (BLOWERS, 

LOUVRES, TRIMS, GAS COMPONENTS, VENT COMPONENTS, ETC.) COULD RESULT IN A SAFETY 

HAZARD AND WILL VOID THE LIMITED LIFETIME WARRANTY.

THIS APPLIANCE MUST NOT BE INSTALLED IN A BATHROOM. 

DO NOT OPERATE WITHOUT CERAMIC CATALYST IN PLACE. 

2.2 GENERAL 

INSTRUCTIONS

W415-1158 / A / 11.19.13

 5

EN

22"

559mm

19 1/4"

487mm

6 7/8"

175mm

23 3/4"

605mm

32 3/8"

822mm

Summary of Contents for WHVF24

Page 1: ...ur gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This is an unvented gas fired heater that uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must b...

Page 2: ...4 MOBILE HOME 10 3 5 MOUNTING THE APPLIANCE 11 3 6 MINIMUM CLEARANCE TO COMBUSTIBLES 12 4 0 FINISHING 13 4 1 SURROUND INSTALLATION REMOVAL 13 4 2 DOOR REMOVAL INSTALLATION 13 4 3 GLASS MEDIA 14 5 0 IGNITION SYSTEM DIAGRAM 15 6 0 OPERATION 16 6 1 LIGHTING AND OPERATING INSTRUCTIONS 16 7 0 ADJUSTMENTS 17 7 1 VENTURI ADJUSTMENT 17 7 2 FLAME CHARACTERISTICS 17 8 0 MAINTENANCE 18 8 1 ANNUAL MAINTENANCE...

Page 3: ...UM CLEARANCES TO COMBUSTIBLES section Side Wall see MINIMUM CLEARANCES TO COMBUSTIBLES section Rating plate see RATING PLATE INFORMATION section Surround see FINISHING section W415 1158 A 11 19 13 3 EN 1 0 INSTALLATION OVERVIEW ...

Page 4: ...tect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance are kept clean The appliance should be inspected before use and at least annually by a qualified ser...

Page 5: ...ERLY GET FRESH AIR AT ONCE HAVE HEATER SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUNG DISEASE ANEMIA THOSE UNDER THE INFLUENCE OF ALCOHOL THOSE AT HIGH ALTITUDES ARE MORE AFFECTED BY CARBON MONOXIDE THAN OTHERS FAILURE TO KEEP THE PRIMARY AIR OPENING S OF THE BURNER S CLEAN MAY RESULT IN SOOTING AND PROPERTY DAMAGE THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE...

Page 6: ...g positions the addition of foreign or unapproved materials or the failure to properly maintain the appliance may result in incomplete combustion of the fuel Incomplete combustion results in soot being deposited inside the firebox as well as surfaces outside the appliance If any soot deposits are observed shut off the appliance immediately and arrange for it to be serviced by a qualified technicia...

Page 7: ...MAX SUPPLY PRESSURE 13 WATER COLUMN LP NOT FOR USE WITH SOLID FUEL WARNING DO NOT ADD ANY MATERIAL TO THE APPLIANCE WHICH WILL COME IN CONTACT WITH THE FLAME DO NOT USE ACCESSORIES NOT APPROVED FOR USE WITH THIS APPLIANCE APPLY LOOSE MATERIAL PER INSTRUCTIONS MANUAL DO NOT APPLY EXTRA MATERIAL OR MATERIAL NOT SUPPLIED WITH THE APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERNATION SERVICE OR MAINT...

Page 8: ...ed to the outside atmosphere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and B Weather stripping has been added on openable windows and doors and C Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panel...

Page 9: ... no door to the adjoining room the volume of the adjoining room may be added to the volume of the room with the heater to get a total unconfined space The total unconfined space 400 ft3 11 3m3 600 ft3 17m3 1000 cubic feet 28 3m3 Maximum BTU h 1000x1000 20 000 BTU h 50 19 3 EXAMPLE 2 If in this example a solid door separates Room 1 from Room 2 the volume of Room 2 could not be used In this case the...

Page 10: ...ordance to local codes In the absence of local codes install to the current CAN CSA B149 1 Installation Code in Canada or to the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States When flexing any gas line support the gas valve so that the lines are not bent or kinked Check for gas leaks by brushing on a soap and water solution WARNING RISK OF FIRE EXPLOSION OR ASPHYXIATION EN...

Page 11: ...ts are facing upward NOTE The mounting screws must go into a wall stud or proper anchors D Mount the appliance onto the mounting bracket by placing the appliance into the slots until it is secured in place see Figure 2 NOTE Ensure the appliance is resting securely in the slots E Further secure the bottom of the appliance with the two screws see Figure 3 NOTE It is strongly recommended that the app...

Page 12: ...54mm MIN 20 508mm MIN 10 254mm MIN 3 6 MINIMUM CLEARANCE TO COMBUSTIBLES MINIMUM CLEARANCES TO COMBUSTIBLES 20 508mm to top 7 177 8mm to sides 10 254mm to bottom 36 914 4mm to rear TYPICAL INSTALLATION ALCOVE INSTALLATION SIDE VIEW Clearances are measured from the appliance ALCOVE INSTALLATION TOP VIEW ...

Page 13: ...E PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED FACING AND OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS CO...

Page 14: ...h mild dish soap drain rinse thoroughly and dry before placing over the burner CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION BEFORE APPLYING THE CLEANED GLASS ENSURE THAT IT IS DRY DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE IF REPLACING USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED DEALER DISTRIBUTOR GLASS MEDIA OVER THE BURNER MUST NOT BE...

Page 15: ... 15 EN 5 0 IGNITION SYSTEM DIAGRAM WARNING ENSURE ALL POWER IS TURNED OFF BEFORE HARD WIRING THIS APPLIANCE CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR ELECTRODE VALVE KNOB PILOT THERMOCOUPLE ...

Page 16: ...E CLOCKWISE TO OFF 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS IF YOU SMELL GAS INCLUDING NEAR THE FLOOR STOP FOLLOW B OF THE OPERATING INSTRUCTIONS IF YOU DON T SMELL GAS GO TO THE NEXT STEP 5 TURN MANUAL SHUTOFF VALVE COUNTER CLOCKWISE TO ON 6 TURN ON MAIN BURNER IF THE APPLIANCE WILL NOT OPERATE FOLLOW THE INSTRUCTIONS TO TURN OFF GAS AND CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER OPERATING IN...

Page 17: ...that has been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will cause a more yellow flame but can lead to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTE...

Page 18: ...APPLIANCE MAY BE HOT DO NOT SERVICE UNTIL APPLIANCE HAS COOLED DO NOT USE ABRASIVE CLEANERS DO NOT PAINT THE PILOT ASSEMBLY WARNING 37 1A WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION LET THE APPLIANCE COOL COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE NEVER VACUUM HOT EMBERS DO NOT PAINT THE PILOT ASSEMBLY This appliance will require maintenance which should be planne...

Page 19: ...10 hours of operation with a recommended fireplace glass cleaner Thereafter clean as required If the glass is not kept clean permanent discoloration and or blemishes may result HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS WARNING 6 1 If the appliance is equipped with plated parts you must clean fingerprints or other marks from the plated surfaces b...

Page 20: ...EALER 41 1 FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING COMPONENTS REF NO PART NO DESCRIPTION 1 G010 0028 ASSEMBLY BURNER 2 G010 0032 ASSEMBLY DOOR 3 G010 0035 ASSEMBLY CURVED FRONT GLASS 4 G137 0001 CERAMIC CATALYST C W CAN 5 G240 0002N ODS NG 5 G240 0002...

Page 21: ...a or combustion chamber Check that the glass logs rocks or media are correctly positioned Open air shutter to increase the primary air Check the input rate check the manifold pressure and orifice size as specified in the instructions Check that the door gasketing is not broken or missing and that the seal is tight White grey film forms Sulphur from fuel is being deposited on glass logs or combusti...

Page 22: ...ber heat exchanger plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single claim During the first 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime war...

Page 23: ...W415 1158 A 11 19 13 23 EN 12 0 SERVICE HISTORY 43 1 ...

Page 24: ...aces Outdoor Fireplaces Gourmet Grills Fireplaces Heating Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Trans Canada Highway Montreal Quebec Canada H4T 1A3 ...