Diving Hookah Operation 

Location:

 Position the diving hookah on a stable and reasonably level surface. The diving hookah does not 

contain any lubricating fluids so the surface does not need to be perfectly level. Locating the diving hookah on 
an excessively sloped surface however could al

low it to slowly ‘creep’ due to vibration while running.

 

Ensure there is sufficient room around the diving hookah to allow a free flow of cooling air to the cooling fan 
and from the cooling fan. 

Be mindful that the diving hookah draws breathing air from underneath the cooling fan cover. The air being 
drawn into the cooling fan is the air that will be supplied to the diver. Be constantly mindful of the air quality at 
the cooling fan. Boat motors, generators, fuel supplies and batteries are all potential sources of breathing air 
contamination. 
 

Power Connection:

 Connect the diving hookah only to a 24 volt battery. Connect the 

RED

 positive cable to the 

positive (+) battery terminal. Connect the 

BLACK

 negative cable to the negative (-) battery terminal. Ensure the 

connections are secure. 

The unit is fitted with 1.8m cables. Extending the cables over greater distances will result in a drop in voltage 
reaching the electric motor. Lower voltages reaching the motor can cause damage and overheating. 
Additionally lower voltage will reduce the rpm of the motor thereby reducing the air output. Any extensions to 
the power cables should be carried out by a suitably qualified electrical specialist and may require upgrading 
the cables to a larger diameter than those supplied to compensate for additional cable length. 
 

Hose Connection:

 The supplied hose/regulator assembly should be connected to the breathing air outlet 

located on the end of the diving hookah filter assembly. The hose connects by simply pushing the male hose 
connector into the female air coupling. Ensure that the chrome outer ring of the air outlet clicks back into place 
securely. Ensure that the connection is secure. 
 

Switching The Diving Hookah On:

 The 

diving hookah’s Electrical Control Box incorp

orates a red ON/OFF switch. 

The diving hookah is switched on by pulling the red switch to the upper position. The compressor will then run 
and pressurise the air storage tank to approximately 10 Bar. The compressor will then switch off automatically. 
The compressor will cycle on and off as air is used by the diver, constantly re-pressurising the air storage tank 
to approximately 10 Bar. 
 

Outlet Pressure Regulation:

 The outlet air pressure (air to the diver via the filter) is reduced by a pressure 

regulator. The pressure regulator is mounted under the pressure gauge and the pressure gauge displays the 
regulated outlet air pressure. The pressure regulator can be adjusted by pulling the red adjustment knob up 
until it clicks and then turning the knob until the desired outlet pressure is obtained. Once adjusted, the knob 
should be pushed back into place until it clicks. The outlet air pressure will be factory set to approximately 4 
Bar and adjustment is not generally necessary. Raising the outlet air pressure can place excessive strain on the 
diving air hose, fittings and 2

nd

 stage regulator/mouthpiece. 

 

After Use:

 After diving operations are completed the diving hookah should be switched off by pushing the red 

ON/OFF switch to the lower position. The air storage tank should be drained of air via the drain valve located 
on the lower side of the tank. Moisture which has accumulated in the tank during operation will also drain and 
this is quite normal. It is also normal for the moisture to contain discolouration. 
 

 

 