PACIFIC E27 – EG27
30 |
P a g e
PACIFIC E27 – EG27 Rev.00
Nardi Compressori – www.nardicompressori.com
When the electronic control panel is turned on, the display shows a screen that
displays “NARDI AIR COMPRESSOR” with the serial number of the electronic control
panel. It will remain on the display for a few seconds before it moves on to the next
screen.
The next screen shows by itself and it indicates the pressure of the system
“PRESSURE” in BAR or PSI, hours of operation “WORK TIME” in hours or “h” and the
stop pressure of the compressor which in the picture on the left was set at 100 bar
(this value can be modified).
To move to the next screen you must press the PAGE button.
In this screen, the cursor ”_” blinks next to the word “ON”. Pressing the arrow buttons
▲(up) or ▼ (down), you can modify the time that the condensate drain remains open,
in seconds “sec”. Pressing the “PAGE” button the blinking cursor “_” will move next to
the word “OFF”. Pressing the arrow buttons ▲(up) or ▼ (down), you can change the
time interval between cycles of condensate drain, in minutes “min”. The standard parameters are: “ON” open 5 seconds
- “OFF” closed 15 minutes.
To move to the next screen you must press the PAGE button again.
This screen shows the number of times the condensate has been drained under the
message "TIME NUMBER CONDENSATE BLOW WATER ". This parameter indicates
the number of cycles of pressurization and depressurization suffered by separators,
filter, and various components of the compressor. This information is useful for replacement of components under
pressure based on usage.
To move to the next screen you must press the PAGE button again.
In this screen you can change the mode in which you use the compressor. The
default mode set by Nardi Compressori is manual “MANUAL”, this means that once
the compressor reaches the maximum pressure it turns off automatically. In order to
restart the compressor, you need to manually press the “START” button.
To change the mode from “MANUAL” to “AUTOMATIC” you need to press the arrow buttons ▲(up) ▼(down).
In “AUTOMATIC” mode the compressor turns off automatically when it reaches the
maximum pressure but it restarts automatically at the minimum pressure level set up.
This mode is normally used when the compressor is connected to a storage system of
cylinders or canisters. When the minimum pressure is reached the compressor restarts
keeping all the stored air under pressure.
To move to the next screen you must press the PAGE button again.
In this screen you can change the maximum pressure at which the compressor will
automatically stop “COMPRESSOR MAXIMUN PRESSURE”.
Pressing the arrow buttons ▲(up) o ▼ (down) you can change the value entered.
The highest value in the scale is calculated based on the characteristics of the
compressor. This is set by NARDI COMPRESSORI at 225 BAR or 330 BAR according to the maximum pressure
allowed by the compressor.
To move to the next screen you must press the PAGE button again.
NARDI
AIR COMPRESSOR
900385
PRESSURE 0BAR
WORK TIME 1h
STOP PRE. 225bar
CONDENSATE BLOW
WATER ON _ 3 sec
OFF 15 min
TIME NUMBER
CONDENSATE BLOW
WATER 5
MODE
MANUAL
MODE
AUTOMATIC
COMPRESSOR
MAXIMUM PRESSURE
225 bar