PACIFIC M35
16 |
P a g e
PACIFIC M35 REV.01-17 COD. PA201-M35-ENG
Nardi Compressori – www.nardicompressori.com
6
OPERATION AND USE
6.01 PREPARING TO START THE COMPRESSOR:
This compressor has been designed to compress ambient air. It is forbidden to modify the intake to
compress air other than ambient air. The compressor is constructed to compress air with a percentage
of oxygen content which must not exceed 21%. The use of the compressor to draw/compress air with a
higher content of oxygen or using other gases, can lead to breakage or to EXPLOSION of the
compressor.
All compressors are tested by NARDI COMPRESSORI before delivery, but for powering it on you need to follow these
safety steps:
Before turning on the machine, all the operators of the compressor must read carefully the User’s and
Maintenance Manual.
If the compressor has not been in operation for a period longer than twelve months we recommended changing
the oil, changing the intake filter and doing a checkup of the compressor by a technician.
Test the condensate drain valve by pressing the button PURGE and test the emergency button on the electronic
control panel.
Check that the oil level be at MAX (full). If the compressor is driven by a fuel engine also check the oil level of the
fuel engine reading the relevant manual. Before powering on the compressor, make sure the fuel tank is full.
Never refuel the engine’s fuel tank while the compressor is running.
Every time you turn on the compressor follow these steps and if something is not working properly, do not turn on
the compressor, and run a maintain check or contact a technician to solve the problem.
6.02 STARTING THE COMPRESSOR:
Compressor driven by an electric motor with Automatic Control System:
This model is provided with an electronic control panel which controls the compressor in all its functions.
Before starting the compressor, follow all the steps in 6.01 above and after press the START button. Automatic
condensate drain cycles will begin to execute the opening of the valve every 6 minutes.
At maximum pressure, the machine will automatically shut down.
Press the STOP / emergency button to stop the compressor (once pressed the emergency button needs to be reset).