7.07 ALARM OIL LEVEL:
When the oil level drops below the minimum threshold, an alarm (visible and acoustic),
is triggered, with a message on the display that shows the scarcity of oil in the
compressor
.
It is necessary to do a top up of oil to the compressor, as described above, up to the maximum level. Press "RESET" on
the front of the electronic control panel, so as to reset the alarm and then "START" to start the compressor. In the event
that, within a short time, the oil level alarm is triggered again, you need to call a technician to check any possible
anomaly.
7.08 CHANGE INTAKE FILTER:
The filter traps any impurities present in the environment. It must be
replaced at regular intervals as indicated in the maintenance checklist.
It should not be washed but replaced.
The steps for changing the filter are as follows:
•
Release the latches on the lid and remove the filter cartridge.
•
Clean with a damp cloth inside the filter housing and the cap.
Insert the new filter cartridge and close the lid.
7.09 MAINTENANCE OF INTERMEDIATE SEPARATORS:
In the compression phase the air undergoes a temperature increase that from one stage
and the other is cooled by a series of cooling coils (intercooler). This sudden thermal
change produces condensation which is eliminated by intermediate separators. Within
the intermediate separators there are filtering elements that need to be changed
periodically.
The steps for changing the filtering elements are as follows:
With the compressor switched off, depressurize the separators using the
condensate drain tap.
Unscrew the bottom part of the separators.
Unscrew the filtering element and replace it with a new one.
Wipe the bottom of the separator housing with a damp cloth and make sure there
is no corrosion.
Replace the O-rings.
Close the separator securely.
When used at a pressure exceeding 300 bars, intermediate separators must be replaced after 10000 hours.