PACIFIC M35
27 |
P a g e
PACIFIC M35 REV.01-17 COD. PA201-M35-ENG
Nardi Compressori – www.nardicompressori.com
7.22 DESCRIPTION FRONT PANEL:
The electronic control system NARDI COMPRESSORI monitors the proper operation of the compressor:
manages the pressures and temperatures of one or more compression stages; It manages the inlet pressure
of the air or nitrogen; It manages how to use manual or automatic; displayed it keeps the working hours of
the compressor and signals the need to perform the service after the hours of work scheduled;
management of the electric motor; setting the maximum and minimum pressure during use; Menus
available in four languages; Display contrast adjustable; It manages alarms and failures indicating precisely
the problem; hardware outputs for interfacing with other
operating systems.
1. Start button compressor
2. Stop button or Emergency.
3. Door lock main switch.
4. Button form feed (PAGE)
5. Button up (
▲
).
6. Button down (
▼
).
7. Reset button (RESET)
8. Yellow LED information (ALARM NOT BLOCKING)
9. Green led compressor running.
10. Red LED for general alarm (ALARM BLOCKING)
7.23 USE OF ELECTRONIC:
WARNING:
The control panel is an advanced component that allows you to monitor the
compressor and at the same time change the parameters of use of the same.
The control panel is set by Nardi Compressori at time of production with standard or custom
parameters. The control panel is composed of the following buttons:
LINE SWITCH:
This switch is used to give power to the electrical panel and all electrical parts. When the
"0" no component is powered and it is important pull the plug in the case of service. The switch in position
"I" blocks the opening of the control cabinet and the compressor and all its electrical components are
supplied.
STOP BUTTON:
This switch is reset and turns off the compressor, so once you have pressed to rotate the
push-button to get it out and resume the normal position.
START BUTTON
: Used to turn on the compressor.
BUTTONS PAGE -
▲
-
▼
- RESET:
Used to scroll through the menu of the control panel and to modify
parameters
LIGHT INFORMATION:
This yellow LED indicates that the compressor has a fault.
COMPRESSOR LIGHT ON
: This green LED indicates that the compressor is running.
LIGHT GENERAL ALARMS
: This red LED flashing light indicates a problem or an alarm.