WARNING:
To proceed with the maintenance of the oven it is necessary to turn off the
Burners
and wait 24 hours to
ensure that all the components are at ambient temperature.
3. MAINTENANCE
3.1. General Maintenance
- It is recommended to keep the
Combustion chamber
clean, as far as possible, to ensure proper operation
and thus prolong the useful life of the insulating material.
- It is recommended to check the status of the thermocouple, the ignition device, the gas valve, the regulator
and the non-return valve. If any of these elements suffers any type of deterioration, contact the Nargesa
technical service.
- It is required the replacement of the thermocouple, the ignition device, the gas valve, the regulator and the
non-return valve every 5 years. It is advisable that the technical service of Nargesa make this substitution.
- It is recommended to check periodically the condition of the isolating material to ensure good insulation of
the
Combustion chamber
with the outside of the oven. In case the isolating material is degraded, it can be
damaged immediately and irreparable damage will be caused to the metallic enclosure.
- It is recommended to replace the insulating material every 1000 hours of operation.
Picture 7. Insolating kit
Summary of Contents for H2
Page 2: ...Thanks for choosing our brand www nargesa com...
Page 25: ...Tecnichal Annex Furnace H2 List of parts Location of components Gas layout...
Page 27: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 3...
Page 28: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 4...
Page 29: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 5...
Page 30: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 6...
Page 31: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 7...
Page 32: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 8 Location of components...
Page 33: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 9 Gas layout...