Thank you for buying the NaRiKa Genecon V3 (manual electricity generator
for elementary school)
Please pay attention to the following precautions when conducting the
experiments.
●Contents of the set: Genecon V3, dedicated output cord (red/black)
How to use the Genecon V3
How to insert the cord
Insert the connector part of the dedicated output
cord into the inlet for the dedicated output cord
of the body until a “click” sound is heard.
In doing so, confirm the seal attached to the
connector part of the output cord.
How to generate electricity
Hold the Genecon V3 in one hand and turn the handle in either the right-handed or left-
handed direction shown by the arrow to generate electricity. Connect the plastic covered clip
of the dedicated output cord to the experiment devices.
<Caution on the pole>
With the Genecon V3, the polarity changes depending on the direction that the handle is
turned.
・ With the right-handed seal of the connector upside, when the handle is turned in the
direction of the right-handled arrow (right turn), the red plastic covered clip becomes the
plus pole and the black plastic covered clip becomes the minus pole.
・ With the left-handed seal of the connector upside, when the handle is turned in the
direction of the left-handled arrow (left turn), the red plastic covered clip becomes the plus
pole and the black plastic covered clip becomes the minus pole.
・ When the handle is turned in the opposite direction, the polarities change as well.
Introduction of the relevant parts
By inserting the Genecon V3 dedicated adapter, a small lamp or LED can be lit directly.
* Variations of the relevant products will be expanded.
* The dedicated adapter can be used for the Genecon V3.
Experimental devices that use the Genecon V3 and
examples of experiments
The use of the dedicated output cord allows the Genecon V3 to be used as a substitute
for a battery.
● Small lamp, LED
Relevant goods P70-0392 Small lamp socket with lead wire
P30-0596-01 / 02 / 03 LED with protection (with constant current diode)
● Electronic melody, propeller motor
Relevant goods B10-2101-02 Electronic melody (with a slanted stand)
P70-3936 Propeller motor
For right-handed persons, insert the right-handed seal into the upper side.
For left-handed persons, insert the left-handed seal into the upper side.
Experiment to generate electricity
B10-2634-01 Adapter for the Genecon V3 (LED)
B10-2634-02 Adapter for the Genecon V3 (small lamp)
【 Precautions 】
・ Do not expose the product to open flame or fire. Do not spill water on the product.
・
Do not store the product in high-temperature and/or high-humidity environments.
・
Do not drop the product. The impact may damage the product.
・
Be careful of electrical shock. The experiment in which several Genecon V3 units
are connected generates very high voltage, posing the danger of electrical shock.
・
Do not conduct an experiment when several Genecon V3 units are connected to
the condenser.
・
Do not use the product for other purposes than the experiment in science class.
(e.g. charging a cell phone)
・
Turning the handle suddenly in the short circuit condition or with a small resistance
attached may damage the product. Be careful.
・
The polarity changes depending on the direction that the handle is turned. Be sure
to confirm the polarity before connecting to something that has polarity like LEDs
or condensers.
・
If the inner gear breaks, use the [Repair gear set for the Genecon DUE].
Inlet for the dedicated output cord
Handle
Inlet for the dedicated output cord