91
6. Specification
Mainframe
❖
❖
❖
❖
Configuration:
Desktop
❖
❖
❖
❖
Photosensitivity type:
OPC
❖
❖
❖
❖
Original scanning:
One-dimensional solid scanning system through CCD
❖
❖
❖
❖
Copy process:
Dry electrostatic transfer system
❖
❖
❖
❖
Development:
Dry one-component magnetic brush development system
❖
❖
❖
❖
Fusing:
Heating roll system
❖
❖
❖
❖
Resolution:
600dpi
❖
❖
❖
❖
Exposure glass:
Stationary original exposure type
❖
❖
❖
❖
Original reference position:
Rear left corner
❖
❖
❖
❖
Warm-up time:
Less than 30 seconds (20
°
C)
❖
❖
❖
❖
Originals:
Sheet/book/objects
❖
❖
❖
❖
Maximum original size:
A3
L
, 11"
×
17"
L
❖
❖
❖
❖
Copy paper size:
• Trays: A3
L
– A5
K
, 11"
×
17"
L
– 5
1
/
2
"
×
8
1
/
2
"
K
• Bypass: A3
L
– A5
KL
, B6
L
, 11"
×
17"
L
– 5
1
/
2
"
×
8
1
/
2
"
L
• Bypass (non-standard size):
Vertical: 90 – 305mm, 3.5" – 12.0"
Horizontal: 148 – 1,260mm, 5.8" – 49.6"