Mic level:
(60dB dynamic range)
Receive level:
(70dB dynamic range)
Siren level:
(70dB dynamic range)
2.3.6.3 Configuration Jumpers
The configuration options for the AA21-400 can be selected by installing jumpers as
shown below:
RX/CD:
Pins 1-2 :
Radio (Receive) input enabled,
CD input disabled
Pins 2-3 :
CD input enabled,
Radio (Receive) input disabled
EXT SPKR LEVEL :
Installed : 500 mVrms output level
Not installed : 6.5 Vrms output level
2.4 Continued
Airworthiness
Maintenance of the AA21-400 is ‘on condition’ only. Periodic maintenance of this
product is not required.
2.5 Installation
Drawings
DRAWING
REV.
DESCRIPTION
TYPE
SERIAL #
AA21\400\403-0 1.01 AA21-400
Cabin
PA System
Interconnect
All
AA21\400\405-0 1.00 AA21-400
Cabin
PA System
Connector Map
All
AA21\400\521-0
1.20
AA21-400 Cabin PA System
Environmental Qual Form 1200 and up
AA21\400\905-0 1.10 AA21-400
Cabin PA System
Faceplate
All
AA21\400\922-0
1.00
AA21-400 Cabin PA System
Mech. Installation 1015 – 1199
AA21\400\922-0
1.11
AA21-400 Cabin PA System
Mech. Installation 1200 and up
Section 2.0 ends after these Drawings
The document reference is online, please check the correspondence between the online documentation and the printed version.