2.4.2
Cautions
CAUTION:
Do not bundle any lines from this unit
with transmitter coax feed lines. Do not
bundle any logic, audio, or DC power lines from this unit with 400 Hz synchro
wiring or AC power lines. Do not position this unit next to any device with a
strong alternating magnetic field such as an inverter, motor or blower, or
significant audio interference will result.
In all installations, use shielded cable exactly as shown, and ground only as
indicated. Significant problems may result from not following these guidelines.
Failure to follow the installation and wiring instructions provided in this manual
for power and ground connections, including the rating of the circuit breaker,
may lead to damage in the power input circuitry of the unit.
2.4.3
Cabling and Wiring
All wire shall be selected in accordance with the original aircraft manufacturer's Maintenance Instructions
or AC43.13-1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to
MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11.
For shielded wire applications, use Tefzel MIL-C-27500 shielded wire with solder sleeves (for shield
terminations) to make the most compact and easily terminated interconnect. Follow the connector map in
Section 2.7 as required.
Allow 3" from the end of the shielded wiring to the shield termination to allow the connector hood to be
easily installed. Reference the interconnect drawing in Section 2.7 for shield termination details. Note that
the hood is a "clamshell" hood, and is installed after the wiring is complete.
Maintain wire segregation and route wiring in accordance with the original aircraft manufacturers
Maintenance Instructions.
Unless otherwise noted, all wiring shall be a minimum of 22 AWG. Refer to the interconnect drawing for
additional specifications. Check that the ground connection is clean and well secured, and that it shares
no path with any electrically noisy aircraft accessories such as blowers, turn and bank instruments or
similar loads.
2.4.4
Mounting
The RM01 can be bulkhead-mounted in any orientation, using four 6-32 screws. No shock or vibration
isolators are required.
The RM01 must be mounted to a clean metal surface which is electrically bonded to the aircraft ground
plane. The unit is finished with a coating that prevents corrosion. This coating is electrically conductive
and should not be removed for electrical bonding.