NI 9146 Operating Instructions and Specifications
18
ni.com
Physical Characteristics
If you need to clean the chassis, wipe it with a dry towel.
Screw-terminal wiring ............................0.5 to 2.5 mm
2
(24 to 12 AWG)
copper conductor wire with
10 mm (0.39 in.) of insulation
stripped from the end
Torque for screw terminals.....................0.5 to 0.6 N · m
(4.4 to 5.3 lb · in.)
Weight ....................................................643 g (22.7 oz)
Environmental
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2) ...........–40 to 70 °C
Note
To meet this operating temperature range, you must compile your LabVIEW FPGA
application at 40 MHz or slower and follow the guidelines in the installation instructions
for your system.
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ...........–40 to 85 °C
Ingress protection ...................................IP 40
Operating humidity
(IEC 60068-2-56) ...................................10 to 90% RH, noncondensing
Storage humidity
(IEC 60068-2-56) ...................................5 to 95% RH, noncondensing
Maximum altitude...................................2,000 m
Pollution Degree (IEC 60664) ................2
Indoor use only
Shock and Vibration
To meet these specifications, you must panel mount the chassis and affix
ferrules to the ends of the power terminal wires.
Operating shock
(IEC 60068-2-27) ...................................30 g, 11 ms half sine
50 g, 3 ms half sine,
18 shocks at 6 orientations