background image

NI corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI
also has offices located around the world. For telephone support
in the United States, create your service request at 

ni.com/support

or dial 1 866 ASK MYNI (275 6964). For telephone support
outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers,
email addresses, and current events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on NI

trademarks. Other product and company names mentioned herein are trademarks or trade names
of their respective companies. For patents covering NI products/technology, refer to the
appropriate location: 

Help

»

Patents

 in your software, the 

patents.txt

 file on your media, or the

National Instruments Patent Notice

 at 

ni.com/patents

. You can find information about end-user

license agreements (EULAs) and third-party legal notices in the readme file for your NI product.
Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the NI

global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/
export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF
THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
U.S. Government Customers: The data contained in this manual was developed at private
expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR
52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2004—2016 National Instruments. All rights reserved.

373781H-01

Mar16

Summary of Contents for 9263

Page 1: ...GETTING STARTED GUIDE NI 9263 4 AO 10 V 16 Bit 100 kS s ch Simultaneous ...

Page 2: ...ific to the NI 9263 The other components in the system might not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9263 only as described in this document Caution Do not operate the NI 9263 in a manner not specified in this document Product misuse can result in a ha...

Page 3: ...A hazardous voltage is a voltage greater than 42 4 Vpk voltage or 60 VDC to earth ground Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Ensure that devices and circuits connected to the module are properly insulated fro...

Page 4: ...ing terminal to ensure that the terminals are not accessible Safety Voltages Connect only voltages that are within the following limits Channel to channel None Channel to earth ground Continuous 250 Vrms Measurement Category II Withstand 2 300 Vrms verified by a 5 s dielectric withstand test Division 2 and Zone 2 hazardous locations applications Channel to earth ground 60 VDC Measurement Category ...

Page 5: ...lectronics Caution Do not connect the NI 9263 to signals or use for measurements within Measurement Categories II III or IV Note Measurement Categories CAT I and CAT O are equivalent These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II CAT III or CAT IV Measurement Category II is for measurements performed o...

Page 6: ...ations only Follow these guidelines if you are installing the NI 9263 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be ...

Page 7: ...Zone 2 hazardous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9263 in Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution You must make sure that transient disturbances do not exceed 140 of the rated voltage Caution The system shall only be used in an...

Page 8: ...on against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio ...

Page 9: ...gister certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power and input output ports In addition take precautions when designing selecting and installing measureme...

Page 10: ...fications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Note Refer to the device datasheet on ni com manuals for complete specifications 10 ni com NI 9263 Getting Started Guide ...

Page 11: ...NI 9263 Pinout AO0 COM AO1 COM AO2 COM AO3 COM NC COM 0 1 2 3 4 5 6 7 8 9 AO0 COM AO1 COM AO2 COM AO3 COM NC COM 0 1 2 3 4 5 6 7 8 9 NI 9263 Getting Started Guide National Instruments 11 ...

Page 12: ...e to a single terminal on the NI 9263 Table 1 Signal Descriptions Signal Description AO Analog output signal connection COM Common reference connection to isolated ground NC No connection Connecting a Load You can connect a load to each channel of the NI 9263 12 ni com NI 9263 Getting Started Guide ...

Page 13: ...cation Connections If your application is subject to high vibration NI recommends that you follow these guidelines to protect connections to the NI 9263 Use ferrules to terminate wires to the detachable connector Use the NI 9927 backshell kit with the NI 9263 with screw terminal or the NI 9981 backshell kit with the NI 9263 with spring terminal NI 9263 Getting Started Guide National Instruments 13...

Page 14: ...uals RELATED INFORMATION C Series Documentation Resources ni com info cseriesdoc Services ni com services Installs with the software NI 9263 Datasheet NI RIO Help LabVIEW FPGA Help NI 9263 Datasheet NI DAQmx Help LabVIEW Help 14 ni com NI 9263 Getting Started Guide ...

Page 15: ...oduct Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC f...

Page 16: ...ucts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI glo...

Reviews: