NI 9921/9922 Outdoor IP Enclosure Installation Guide
8
ni.com
The pin number is marked on the inside of the field termination connector, next to the respective
terminal, as shown in Figure 9.
Figure 9.
Male and Female M12 Termination Connector Pinouts
Male M12 Field Termination Cable
On the M12 Trigger male field termination connector, connect PFI 0 to the Pin 4, PFI 1 to Pin 2, and
Ground to Pins 1 and 3.
The pin number is marked on the inside of the field termination connector, next to the respective
terminal, as shown in Figure 9.
Building an IP Rated RJ45 Cable
Refer to the
SCPFE Assembly/Wiring Instructions
document included in the field termination connector
kit for instructions about how to build an IP rated Ethernet cable.
Refer to Figure 10 while completing the following steps to attach the external cables:
Figure 10.
Connecting External Cables/Components
1
Male M12 Field Termination Pinout
2
Female M12 Field Termination Pinout
1
Ethernet Cable
2
M12 Power Cable
3
M12 Trigger Cable
4
Glands/Gaskets
5
I/O Cables