A-6
|
ni.com
Appendix A
Specifications
Table A-1.
Low Power (100 to 120 VAC, 16 A, 50/60 Hz Input) (Watts)
24U or 40 U Configurations
Low Speed Fan Panel
High Speed Fan Panel
Max. Internal Temp
Max. Internal Temp
45 °C
50 °C
45 °C
50 °C
40 °C Ambient
(Maximum Mfg Environment)
500 W
1,350 W
1,500 W
1,500 W
28 °C Ambient
(Typical Mfg Environment)
1,870 W
1,870 W
1,620 W
1,620 W
23 °C Ambient
(Typical Room Temperature)
1,870 W
1,870 W
1,620 W
1,620 W
Table A-2.
Low Power (200 to 240 VAC, 16 A, 50/60 Hz Input) (Watts)
24U or 40 U Configurations
Low Speed Fan Panel
High Speed Fan Panel
Max. Internal Temp
Max. Internal Temp
45 °C
50 °C
45 °C
50 °C
40 °C Ambient
(Maximum Mfg Environment)
500 W
1,350 W
1,500 W
1,500 W
28 °C Ambient
(Typical Mfg Environment)
2,550 W
3,400 W
3,540 W
3,540 W
23 °C Ambient
(Typical Room Temperature)
3,400 W
3,790 W
3,540 W
3,540 W