© National Instruments
|
A-1
A
Specifications
This section contains specifications for the ATE Core Configurations.
Mechanical
Contact National Instruments for the weight of your rack as configured. To estimate your rack’s
weight without a scale, add the weight of each piece of equipment in the rack to the following base
values:
Base configuration weight
(rack, fan panel, power entry panel, PDU) ....... 320 lb. (145 kg)
Ballast plate weight (each) ............................... 45 lb. (20.4 kg)
Maximum weight (Base configuration, and all equipment installed, stored, or attached to rack)
24U, 40U rack........................................... 1,000 lb. (453.5 kg), evenly distributed across
each caster
Keyboard shelf (optional)................. 30 lb. (13.6 kg)
Storage drawer (optional) ................. 30 lb. (13.6 kg)
The outlet circuit breaker(s) on the power entry panels PEP-116 and PEP-130 for Low and
Mid power ATE Core Configurations are rated for an impact energy level of IK06 (1J),
when tested with a direct vertical impact per IEC 61010-1, 3rd Ed., Table 15 and Clause 8.2.
The circuit breakers should be guarded against impacts exceeding 1J.
Core System Hardware
24U Rack Dimensions
System height ................................................... 53.5 in. (1,358.9 mm)
System width .................................................... 23 in. (584.2 mm)
System depth..................................................... 31.5 in. (800 mm)
Mountable depth ............................................... 29.5 in. (749.3 mm)
Max static load.................................................. 1,000 lb. (453.5 kg), evenly distributed across
each caster