background image

4

|

ni.com

|

BNC-2120 Installation Guide

To connect the BNC-2120 to your DAQ device, complete the following steps. Consult your 
computer or PXI/PXI Express chassis user manual for specific instructions and warnings.

Note

If you have not already installed your DAQ device, refer to the 

DAQ Getting 

Started 

guides for instructions.

Caution

Do 

not

 connect the BNC-2120 to any device other than National 

Instruments E/M/S/X Series multifunction DAQ devices. Doing so can damage the 
BNC-2120, the DAQ device, or the host computer. National Instruments is 

not

 liable 

for damage resulting from these connections.

1.

Place the BNC-2120 near the host computer or PXI/PXI Express chassis or use the optional 
DIN Rail Mounting kit for UMI-FLEX-6 and BNC boxes (Part Number 777972-01), which 
you can order from National Instruments at 

ni.com

.

Caution

Do 

not

 connect input voltages greater than 42.4 V

pk

/60 VDC to the 

BNC-2120. The BNC-2120 is not designed for any input voltages greater than 
42.4 V

pk

/60 VDC, even if a user-installed voltage divider reduces the voltage to within 

the input range of the DAQ device. Input voltages greater than 42.4 V

pk

/60 VDC can 

damage the BNC-2120, all devices connected to it, and the host computer. Overvoltage 
can also cause an electric shock hazard for the operator. National Instruments is 

not

 

liable for damage or injury resulting from such misuse.

2.

Connect the BNC-2120 to the DAQ device using the appropriate cable for your DAQ 
device, as listed in Table 1.

Caution

To ensure the specified EMC performance, operate this product only with 

shielded cables and accessories.

Table 1.  

BNC-2120 Cabling Options

Number 

of Pins

DAQ Device

Shielded 

Recommended Cable

Unshielded 

Cable

68-pin

DAQCard E Series, 
NI PCI/PCIe/PXI/PXIe M Series

*

NI 6143 S Series,
PCIe/PXIe/USB X Series 

SHC68-68-EPM

RC68-68

PCI/PXI E Series, 
USB Mass Termination M Series

*

NI 611

x

/612

x

/613

x

 S Series

SH68-68-EPM

R6868

100-pin

PCI/PXI E Series

SH1006868

Caution

: For compliance with Electromagnetic Compatibility (EMC) requirements, this product must 

be operated with shielded cables and accessories. If unshielded cables or accessories are used, the EMC 
specifications are no longer guaranteed unless all unshielded cables and/or accessories are installed in a 
shielded enclosure with properly designed and shielded input/output ports.

*

 You cannot connect the BNC-2120 to Connector 1 of NI 6225/6255 devices.

 Do 

not

 use the R6868 cable with NI 6115/6120 S Series devices; use 

only

 the SH68-68-EPM cable.

Summary of Contents for BNC-2120

Page 1: ...ing I O TIO connection Two user defined BNC connectors A function generator with the following outputs Frequency adjustable TTL compatible square wave Frequency and amplitude adjustable sine wave or t...

Page 2: ...Series User Manual the M Series User Manual the S Series User Manual or the X Series User Manual BNC cables 28 16 AWG wire Wire strippers Flathead screwdriver Installing the BNC 2120 Caution When this...

Page 3: ...BNC Connector 24 Power Indicator LED E L R T T S N I NA M U N O I A S T N _ Floating Source FS _ Ground Ref Source GS AO ANALOG OUTPUTS ANALOG INPUTS DIGITAL I O FUNCTION GENERATOR Frequency Selectio...

Page 4: ...damage the BNC 2120 all devices connected to it and the host computer Overvoltage can also cause an electric shock hazard for the operator National Instruments is not liable for damage or injury resu...

Page 5: ...revised its terminal names so they are easier to understand and more consistent among NI hardware and software products The revised terminal names used in this document are usually similar to the nam...

Page 6: ...Move the FS GS switch to the applicable position depending on whether you are measuring a floating source FS or ground referenced source GS analog input signal Refer to the Measuring Floating Signals...

Page 7: ...the temperature reference and thermocouple connector To use the integrated circuit IC temperature reference on the BNC 2120 move the BNC Temp Ref switch above the AI 0 BNC to Temp Ref The integrated c...

Page 8: ...renced single ended RSE mode 3 Connect the resistor to the RES and RES screw terminals You can measure resistors with values ranging from 100 to 1 M 4 Measure VCC on AI 3 and the voltage drop across t...

Page 9: ...onnecting signals to the screw terminals use 28 16 AWG wire with the insulation stripped to 0 28 in Table 2 describes the timing I O BNC and terminal signals on the BNC 2120 Table 2 BNC 2120 Timing I...

Page 10: ...to the general purpose counter 1 PFI 5 P1 5 Programmable Function Interface channel 5 or Port 1 Digital Input Output channel 5 AO SAMP CLK AO Sample Clock Signal As an output this pin is the ao Sample...

Page 11: ...pin can be used to route signals directly to the RTSI bus As an output this pin emits the Ctr0InternalOutput signal PFI 13 P2 5 Programmable Function Interface channel 13 or Port 2 Digital Input Outp...

Page 12: ...with counter 1 connect the PULSES terminal to PFI 3 and connect the UP DN terminal to the P0 7 digital I O terminal the up down pin of counter 1 Refer to Table 2 for more information about PFI 3 and P...

Page 13: ...6 shows an example of how to use the USER 1 and USER 2 BNCs To access the PFI 8 P2 0 CTR 0 SOURCE signal from a BNC connect USER 1 on the screw terminal block to PFI 8 P2 0 with a 28 16 AWG wire Figu...

Page 14: ...each digital line as listed in Table 3 Specifications This section lists the specifications of the BNC 2120 These specifications are typical at 25 C unless otherwise specified Note Refer to your DAQ...

Page 15: ...tions 28 16 AWG wire LED state indicators 8 1 each for lines P0 0 7 Protection DC max V Powered off 5 5 V Powered on 10 5 V Drive Vol 0 6 V 8 mA 1 6 V 24 mA Voh 4 4 V 8 mA 4 V 13 mA Function Generator...

Page 16: ...terminals 2 Output signals PULSES 96 pulses revolution UP DN High for clockwise rotation low for counterclockwise rotation Pulse width 1 s Power Requirement 5 VDC 5 200 mA sourced from the multifuncti...

Page 17: ...is used in a manner not described in this document Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control an...

Page 18: ...NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our En...

Page 19: ...t and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Pa...