background image

Visit 

ni.com/register

 to register your National Instruments product. Product registration

facilitates technical support and ensures that you receive important information updates from
NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,
Austin, Texas, 78759-3504. National Instruments also has offices located around the world.
For telephone support in the United States, create your service request at 

ni.com/support

 or

dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers, email addresses, and current
events.

NI cRIO-9039 Getting Started Guide

  | 

© National Instruments

  | 

17

Summary of Contents for cRIO-9039

Page 1: ...document describes how to begin using the NI cRIO 9039 and NI cRIO 9039 Sync In this document the NI cRIO 9039 and NI cRIO 9039 Sync are inclusively referred to as the cRIO 9039 For more information a...

Page 2: ...been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components m...

Page 3: ...Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in the product specifications These requirements...

Page 4: ...Marine Applications Some products are Lloyd s Register LR Type Approved for marine shipboard applications To verify Lloyd s Register certification for a product visit ni com certification and search f...

Page 5: ...ars damaged in any way 3 Unpack any other items and documentation from the kit Store the device in the antistatic package when the device is not in use Verifying the Kit Contents Verify that the follo...

Page 6: ...ers February 2015 or later NI CompactRIO Device Drivers August 2016 or later For minimum software support information visit ni com info and enter the Info Code swsupport Installing C Series Modules Co...

Page 7: ...n a nonhazardous location the cRIO 9039 can be powered on when you remove modules Connecting the cRIO 9039 The cRIO 9039 has the following connectors LEDs and buttons Figure 2 cRIO 9039 Front Panel 1...

Page 8: ...wire to the cable shield Use shorter wire for better EMC performance For more information about ground connections visit ni com info and enter the Info Code emcground Connecting the cRIO 9039 to Power...

Page 9: ...er supply to the cRIO 9039 1 Ensure that your power supply is powered off 2 Install the ferrite on the negative and positive leads of the power supply as shown in the following figure Figure 3 Install...

Page 10: ...cRIO 9039 When you power on the cRIO 9039 for the first time the device boots into safe mode The POWER LED illuminates the STATUS LED illuminates briefly and then the STATUS LED blinks twice every few...

Page 11: ...system password Note The default username for the cRIO 9039 is admin There is no default password for the cRIO 9039 so you must leave the password field blank when logging in until you set a system pa...

Page 12: ...odule Tip You can use this wizard at anytime to install additional software 7 Click Next 8 Verify that the summary of software to install is correct 9 Click Next to start the installation 10 Click Fin...

Page 13: ...System IP Configuration 1 Put the cRIO 9039 in safe mode and enable the RS 232 serial port by holding the RESET button down for 5 seconds The STATUS LED starts blinking three times every few seconds...

Page 14: ...d RESET button for 5 s Press and hold RESET button for 5 s Run Mode Safe Mode Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold...

Page 15: ...r longer than five seconds or by enabling safe mode in MAX Refer to the Measurement Automation Explorer MAX Help for information about safe mode Blinks four times and pauses The cRIO 9039 is in safe m...

Page 16: ...software or in the absence of such license agreements the National Instruments Software License Agreement available at ni com legal at the time of purchase For a copy of the software licenses applicab...

Page 17: ...your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Express...

Page 18: ...d third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance pol...

Reviews: